NOZZLES SUBSTITUTION
Nozzle Baking Burner
Mod.MF110(DX,SX)(C,CT)
–
MF130(DX,SX) )(C,CT)
–
MF150(DX,SX) )(C,CT)
Unscrew nut C- unscrew nozzle D
–
position new nozzle into air regulator E
–
screw nozzle D
–
screw nut C
Nozzle Turbo Burner
Mod.MF110(DX,SX)(T,CT)
–
MF130(DX,SX) )(T,CT)
–
MF150(DX,SX) )(T,CT)
Unscrew nozzle B blocking nut A
–
change nozzle screwing.