ELECTRICAL SPECIFICATIONS
Voltage 240V
Frequency 60 Hz
Amp 2.5
Maranaforni Ovens is configured for connection to a 240v circuit. Always refer to the equipement data plate
beneath the oven to verify the proper voltage.
Electrical diagrams are located behind control panel and inside motor box, under the oven.
SERIE ROTOFORNO SU&GIU SERIE ROTOFORNO CLASSICO
OVEN COVERING SPECIFICATIONS
DO NOT CONNECT THIS OVEN RATED 240v TO A DIFFERENT VOLTAGE CIRCUIT.
Consult a licensed electrician to connect the oven to your appropriate circuit.
WARNING
–
ELECTRICAL GROUNDING INSTRUCTIONS
This appliance must be electrically grounded in accordance with local codes, or in the absence of
local codes, with the National Electrical code, ANSI/NFPA 70 or the Canadian Electrical code, CSA
C22.1 as applicable.
DO NOT OPEN OVEN CONSOLE OR GAS CONSOLE.
IN CASE IT IS NOT OPERATING PROPERLY CALL FOR SERVICE
OVEN MUST BE INSULATED AND COVERED WITH NON-COMBUSTIBLE MATERIALS OR WITH A
NON-COMBUSTIBLE FACADE
Consider your insulation material (standard dry-wall or sheet rock) as a combustible.
Servicing of this products could expose you to non-safety dust: