Certificate Number: 255416-2516776 Project Number: 2516776 Page Number:74
INSTALLATION AND OPERATION MANUAL
MARANA FORNI srl unipersonale
via Turbina 98 37139 Chievo-Verona-Italia
tel. +39 045 6704503 - fax +39 045 7156118
www.maranaforni.it - [email protected]
Skype: maranaforni
VER
2.1
© Riproduzione vietata
PAG
11 / 27
BEFORE COVERING, PLEASE MAKE SURE TO HAVE A PROPER ACCESS FOR REMOVAL OF
THE EXHAUST HOOD FILTERS.
Covering materials must conform local codes or in the absence of local codes, with the National Fuel Gas
Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1, as applicable.
Oven covering or oven facade must be stay
minimum 1.2”
(30mm) from insulation material: this is for have
better insulation and more air circulation.
DON’T MAKE AN AIRTIG
HT COVERING.
A FREE ACCESS OR A REMOVABLE PANEL WITH AIR GRATING
39,5”square (1000mm²)
MUST BE
PROVIDED AT THE UNDER PART OF THE OVEN: IT ALLOWS ACCESS FOR SERVICE OF MOTORS,
ELECTRICAL COMPONENTS AND GAS BURNER AND AS AIR INTAKE.
Covering top part:
if you want to close your covering making a top, do it after oven drying operation.
Provide an air grating 39,5
”square (1000mm²)
positioned on top.
Covering sides and front:
provide an opening space
39,5”square (1000mm²)
in front at the lower part of the
oven
and an opening space 4”X4” (100mmX100mm)
for thermal feeler inspection to be closed by the
removable Maranaforni table.
WARNING:
KEEP THE AREA AROUND AND BENETH THE OVEN CLEAR OF GRASS, LEAVES AND OTHER
COMBUSTIBLE MATERIALS.
DO NOT USE SPACE BETWEEN THE OVEN LEGS AS MATERIAL STORAGE
.
THIS IS TO AVOID FIRE DAMAGES.
OPERATING INSTRUCTIONS
Operation area must be a brightly area. If not, provide for light appliances. Light must not be dazzling.
Operation area must be aired, ventilated. If not, provide for additional ventilation appliances.
WARNING!
DO NOT OPERATE WITHOUT REMOVABLE MOTOR BOX PANEL.
NEVER OPEN MOTOR BOX.