–90–
UG030A-251 SELF-CONTAINED AIR-COOLED — STANDARD CUBE (Continued)
Operating Pressures
Air Temp. Entering
Condenser °C
Freeze Cycle
Harvest Cycle
Discharge Pressure
Suction Pressure
Discharge Pressure
Suction Pressure
All pressures are in bar. Suction pressure drops gradually throughout the freeze cycle.
10
4.21-3.20
0.50-0
7.00-8.88
1.16-4.16
21
7.98-6.61
0.54-0
7.50-9.30
1.58-4.38
32
11.40-8.91
0.62-0.37
7.78-11.48
1.99-5.40
43
15.48-13.21
1.46-0.71
10.43-12.59
3.15-6.10
Summary of Contents for UG018A
Page 2: ......
Page 6: ...This Page Intentionally Left Blank ...
Page 12: ... 2 This Page Intentionally Left Blank ...
Page 20: ...10 Evaporator Spray Nozzles Toggle Switch Spray Bar Ice Chute ...
Page 36: ...26 dip switch Decrease Cube Size Factory Default Setting Increase Cube Size test button ...
Page 38: ...28 ...
Page 80: ...70 This Page Intentionally Left Blank ...
Page 128: ... 118 This Page Intentionally Left Blank ...
Page 135: ... 125 ...