43
Check Procedure
1. Make sure the thermistor sensors installation
correctly
2. Disconnect thermistor from control board and
measure resistance.
3. Measure temperature at the thermistor.
4. Compare measured resistance/
temperature.Creadings to resistance/temperature
relationship
•
Within 10% of the published resistance value-
Thermistor is good
•
Not within 10% of the published resistancevalue -
Thermistor is defective.