16
Sump Drain Overflow Tube
The sump drain overflow tube is located in the
evaporator water sump.
1. Remove shutters and ice chute.
2. Lift spray bar or disconnect and remove for
easiest access.
3. Pull up on over flow tube to remove.
To replace plug, insert in hole, and push with force to
make a tight seal