–11
7–
UG080A SELF-CONTAINED AIR-COOLED — STANDARD CUBE (Continued)
Operating Pressures
-
Air Temp. Entering
Condenser °C
Freeze Cycle
Harvest Cycle
Discharge Pressure
Suction Pressure
Discharge Pressure
Suction Pressure
All pressures are in bar. Suction pressure drops gradually throughout the freeze cycle.
*: peak fan motor shut down.
10
13.42-28.07*
4.75-3.50
12.60-13.90
8.70-10.40
21
16.60-13.85
4.91-3.50
12.65-13.90
8.70-10.45
32
21.00-17.90
5.38-3.70
12.80-14.01
8.75-10.47
43
25.83-24.30
25.20-4.20
14.25-15.82
9.85-11.74