Refrigeration System
Section 7
7-46
Part No. 80-1100-3
Q1800 SERIES
Self-Contained Water-Cooled
NOTE: These characteristics may vary depending on
operating conditions.
Cycle Times
Freeze Time + Harvest Time = Total Cycle Time
24 Hour Ice Production
Operating Pressures
Q1800 SERIES
Remote
NOTE: These characteristics may vary depending on
operating conditions.
Cycle Times
Freeze Time + Harvest Time = Total Cycle Time
24 Hour Ice Production
Operating Pressures
Air Temp.
Around Ice
Machine
°F/°C
Freeze Time
Harvest
Time
Water Temperature °F/°C
50/10.0
70/21.1
90/32.2
70/21.1
8.7-9.6
9.6-10.5
10.8-11.9
1-2.5
80/26.7
9.0-9.9
9.6-10.6
10.8-11.9
90/32.2
9.1-10.1
9.7-10.7
10.9-12.0
100/37.8
9.2-10.1
9.8-10.7
11.1-12.1
Times in minutes
Air Temp.
Around Ice
Machine
°F/°C
Water Temperature °F/°C
50/10.0
70/21.1
90/32.2
70/21.1
1840
1690
1520
80/26.7
1780
1680
1520
90/32.2
1760
1670
1510
100/37.8
1750
1660
1490
Based on average ice slab weight of 13.0- 14.12lb
Regular cube derate is 7%
Condenser
Water
Consumption
90/32.2 Air Temperature
Around Ice Machine
Water Temperature °F/°C
50/10.0
70/21.1
90/32.2
Gal/24 hours
2000
2670
7750
Water regulating valve set to maintain 240 PSIG discharge pressure
Air Temp.
Around Ice
Machine
°F/°C
Freeze Cycle
Harvest Cycle
Discharg
e
Pressure
PSIG
Suction
Pressure
PSIG
Discharg
e
Pressure
PSIG
Suction
Pressure
PSIG
50/10.0
235-245
36-20
170-190
65-80
70/21.1
235-245
38-20
170-190
65-80
80/26.7
235-245
40-20
170-190
65-80
90/32.2
235-250
42-22
175-190
65-80
100/37.8
235-255
44-22
175-190
65-80
110/43.3
235-260
46-22
175-190
65-80
Suction pressure drops gradually throughout the freeze cycle
Air Temp.
Entering
Condenser
°F/°C
Freeze Time
Harvest
Time
Water Temperature °F/°C
50/10.0
70/21.1
90/32.2
-20/-28.9 to
70/21.1
9.1-10.0
9.8-10.8
10.7-11.7
1-2.5
80/26.7
9.3-10.2
10.1-11.1
10.9-12.0
90/32.2
9.5-10.5
10.3-11.4
11.1-12.2
100/37.8
10.1-11.1
11.1-12.2
11.9-13.0
110/43.3
11.0-12.1
12.1-13.2
12.7-13.9
Times in minutes
Air Temp.
Entering
Condenser
°F/°C
Water Temperature °F/°C
50/10.0
70/21.1
90/32.2
-20/-28.9 to
70/21.1
1770
1650
1540
80/26.7
1735
1615
1510
90/32.2
1700
1580
1480
100/37.8
1620
1480
1400
110/43.3
1500
1380
1320
Based on average ice slab weight of 13.0 - 14.12lb
Regular cube derate is 7%
Ratings with JC1895 condenser, dice or half dice cubes
Air Temp.
Entering
Condenser
°F/°C
Freeze Cycle
Harvest Cycle
Discharg
e
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
-20/-28.9 to
50/10.0
220-250
38-24
160-180
60-80
70/21.1
220-260
40-24
170-180
60-80
80/26.7
250-270
48-24
175-190
70-90
90/32.2
250-280
50-24
180-200
80-90
100/37.8
270-300
52-28
205-215
80-95
110/43.3
300-350
54-28
205-230
80-100
Suction pressure drops gradually throughout the freeze cycle
Summary of Contents for QD0202A
Page 3: ......
Page 14: ...General Information Section 1 1 4 Part No 80 1100 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 34: ...Installation Instructions Section 2 2 20 Part No 80 1100 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 50: ...Maintenance Section 3 3 16 Part No 80 1100 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 93: ...Section 6 Electrical System Part No 80 1100 3 6 37 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 112: ...Electrical System Section 6 6 56 Part No 80 1100 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 135: ...Section 7 Refrigeration System Part No 80 1100 3 7 23 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 168: ...Refrigeration System Section 7 7 56 Part No 80 1100 3 Figure 7 18 Using Pinch Off Tool SV1406 ...
Page 174: ...Refrigeration System Section 7 7 62 Part No 80 1100 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 175: ...Section 7 Refrigeration System Part No 80 1100 3 7 63 THIS PAGE INTENTIONALLY LEFT BLANK ...