Installation Instructions
Section 2
2-12
Part No. 80-1100-3
WATER SUPPLY AND DRAIN LINE SIZING/CONNECTIONS
Figure 2-3. Typical Water Supply Drain Installation
!
Caution
Plumbing must conform to state and local codes.
Location
Water Temperature
Water Pressure
Ice Machine Fitting
Tubing Size Up to Ice
Machine Fitting
Ice Making
Water Inlet
33°F (0.6°C) Min.
90°F (32.2°C) Max.
20 psi (137.9 kPA) Min.
80 psi (551.5 kPA) Max.
3/8" Female
Pipe Thread
3/8" (9.5 mm) minimum
inside diameter
Ice Making
Water Drain
---
---
1/2" Female
Pipe Thread
1/2" (12.7 mm) minimum
inside diameter
Condenser
Water Inlet
33°F (0.6°C) Min.
90°F (32.2°C) Max.
20 psi (137.9 kPA) Min.
150 psi (1034.2 kPA) Max.
Q1300/Q1600/Q1800 - 1/2" Female Pipe Thread
All Others - 3/8" Female Pipe Thread
Condenser
Water Drain
---
---
1/2" Female
Pipe Thread
1/2" (12.7 mm) minimum
inside diameter
Bin Drain
---
---
3/4" Female
Pipe Thread
3/4" (19.1 mm) minimum
inside diameter
SV1626
Summary of Contents for QD0202A
Page 3: ......
Page 14: ...General Information Section 1 1 4 Part No 80 1100 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 34: ...Installation Instructions Section 2 2 20 Part No 80 1100 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 50: ...Maintenance Section 3 3 16 Part No 80 1100 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 93: ...Section 6 Electrical System Part No 80 1100 3 6 37 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 112: ...Electrical System Section 6 6 56 Part No 80 1100 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 135: ...Section 7 Refrigeration System Part No 80 1100 3 7 23 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 168: ...Refrigeration System Section 7 7 56 Part No 80 1100 3 Figure 7 18 Using Pinch Off Tool SV1406 ...
Page 174: ...Refrigeration System Section 7 7 62 Part No 80 1100 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 175: ...Section 7 Refrigeration System Part No 80 1100 3 7 63 THIS PAGE INTENTIONALLY LEFT BLANK ...