Refrigeration System
Section 7
7-40
Part No. 80-1100-3
Q800 SERIES
Self-Contained Air-Cooled
NOTE: These characteristics may vary depending on
operating conditions.
Cycle Times
Freeze Time + Harvest Time = Total Cycle Time
24 Hour Ice Production
Operating Pressures
Q800 SERIES
Self-Contained Water-Cooled
NOTE: These characteristics may vary depending on
operating conditions.
Cycle Times
Freeze Time + Harvest Time = Total Cycle Time
24 Hour Ice Production
Operating Pressures
Air Temp.
Entering
Condenser
°F/°C
Freeze Time
Harvest
Time
Water Temperature °F/°C
50/10.0
70/21.1
90/32.2
70/21.1
8.9-10.2
9.7-11.1
10.3-11.9
1-2.5
80/26.7
9.3-10.7
10.2-11.7
10.9-12.5
90/32.2
10.3-11.9
11.4-13.1
12.3-14.1
100/37.8
12.1-13.8
13.3-15.2
14.4-16.5
Times in minutes
Air Temp.
Entering
Condenser
°F/°C
Water Temperature °F/°C
50/10.0
70/21.1
90/32.2
70/21.1
800
740
700
80/26.7
770
710
670
90/32.2
700
640
600
100/37.8
610
560
520
Based on average ice slab weight of 5.75- 6.50 lb
Regular cube derate is 7%
Air Temp.
Entering
Condenser
°F/°C
Freeze Cycle
Harvest Cycle
Discharg
e
Pressure
PSIG
Suction
Pressure
PSIG
Discharg
e
Pressure
PSIG
Suction
Pressure
PSIG
50/10.0
220-280
31-18
135-180
65-90
70/21.1
220-280
32-18
140-180
70-90
80/26.7
225-280
36-20
140-180
70-95
90/32.2
260-295
38-22
150-200
80-100
100/37.8
300-330
40-24
210-225
80-100
110/43.3
320-360
44-26
210-240
85-120
Suction pressure drops gradually throughout the freeze cycle
Air Temp.
Around Ice
Machine
°F/°C
Freeze Time
Harvest
Time
Water Temperature °F/°C
50/10.0
70/21.1
90/32.2
70/21.1
8.7-10.1
9.5-11.0
10.9-12.5
1-2.5
80/26.7
8.9-10.2
9.7-11.1
11.0-12.7
90/32.2
9.0-10.3
9.8-11.3
11.2-12.9
100/37.8
9.1-10.5
10.0-11.5
11.4-13.1
Times in minutes
Air Temp.
Around Ice
Machine
°F/°C
Water Temperature °F/°C
50/10.0
70/21.1
90/32.2
70/21.1
810
750
670
80/26.7
800
740
660
90/32.2
790
730
650
100/37.8
780
720
640
Based on average ice slab weight of 5.75- 6.50lb
Regular cube derate is 7%
Condenser
Water
Consumption
90/32.2 Air Temperature
Around Ice Machine
Water Temperature °F/°C
50/10.0
70/21.1
90/32.2
Gal/24 hours
640
1420
6000
Water regulating valve set to maintain 230 PSIG discharge pressure
Air Temp.
Around Ice
Machine
°F/°C
Freeze Cycle
Harvest Cycle
Discharg
e
Pressure
PSIG
Suction
Pressure
PSIG
Discharg
e
Pressure
PSIG
Suction
Pressure
PSIG
50/10.0
225-235
33-20
160-185
65-85
70/21.1
225-235
34-20
165-185
70-85
80/26.7
225-235
34-20
165-185
70-85
90/32.2
225-235
36-22
165-185
70-85
100/37.8
225-235
36-22
165-185
70-85
110/43.3
225-240
38-24
170-190
75-90
Suction pressure drops gradually throughout the freeze cycle
Summary of Contents for QD0202A
Page 3: ......
Page 14: ...General Information Section 1 1 4 Part No 80 1100 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 34: ...Installation Instructions Section 2 2 20 Part No 80 1100 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 50: ...Maintenance Section 3 3 16 Part No 80 1100 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 93: ...Section 6 Electrical System Part No 80 1100 3 6 37 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 112: ...Electrical System Section 6 6 56 Part No 80 1100 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 135: ...Section 7 Refrigeration System Part No 80 1100 3 7 23 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 168: ...Refrigeration System Section 7 7 56 Part No 80 1100 3 Figure 7 18 Using Pinch Off Tool SV1406 ...
Page 174: ...Refrigeration System Section 7 7 62 Part No 80 1100 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 175: ...Section 7 Refrigeration System Part No 80 1100 3 7 63 THIS PAGE INTENTIONALLY LEFT BLANK ...