Refrigeration System
Section 7
7-36
Part No. 80-1100-3
Q370 SERIES
Self-Contained Air-Cooled
NOTE: These characteristics may vary depending on
operating conditions.
Cycle Times
Freeze Time + Harvest Time = Total Cycle Time
24 Hour Ice Production
Operating Pressures
Q370 SERIES
Self-Contained Water-Cooled
NOTE: These characteristics may vary depending on
operating conditions.
Cycle Times
Freeze Time + Harvest Time = Total Cycle Time
24 Hour Ice Production
Operating Pressures
Air Temp.
Entering
Condenser
°F/°C
Freeze Time
Harvest
Time
Water Temperature °F/°C
50/10.0
70/21.1
90/32.2
70/21.1
10.3-11.7
11.7-13.4
12.6-14.4
1-2.5
80/26.7
11.3-12.9
12.6-14.4
13.9-15.8
90/32.2
12.9-14.7
13.9-15.8
15.4-17.6
100/37.8
14.5-16.5
16.1-18.4
17.3-19.7
Times in minutes
Air Temp.
Entering
Condenser
°F/°C
Water Temperature °F/°C
50/10.0
70/21.1
90/32.2
70/21.1
360
320
300
80/26.7
330
300
275
90/32.2
295
275
250
100/37.8
265
240
225
Based on average ice slab weight of 2.94 - 3.31lb
Air Temp.
Entering
Condenser
°F/°C
Freeze Cycle
Harvest Cycle
Discharg
e
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
50/10.0
200-250
60-34
145-165
75-95
70/21.1
215-250
60-36
150-170
85-100
80/26.7
250-290
65-38
165-185
90-110
90/32.2
260-330
70-40
175-195
100-120
100/37.8
300-380
80-41
195-220
130-150
110/43.3
310-390
80-42
200-225
135-155
Suction pressure drops gradually throughout the freeze cycle
Air Temp.
Around Ice
Machine
°F/°C
Freeze Time
Harvest
Time
Water Temperature °F/°C
50/10.0
70/21.1
90/32.2
70/21.1
10.3-11.7
11.0-12.5
12.2-13.9
1-2.5
80/26.7
10.6-12.1
11.3-12.9
12.6-14.4
90/32.2
11.0-12.5
11.7-13.4
13.1-14.4
100/37.8
11.3-12.9
12.2-13.9
13.6-15.5
Times in minutes
Air Temp.
Around Ice
Machine
°F/°C
Water Temperature °F/°C
50/10.0
70/21.1
90/32.2
70/21.1
360
340
310
80/26.7
350
330
300
90/32.2
340
320
290
100/37.8
330
310
280
Based on average ice slab weight of 2.94 - 3.31lb
Condenser
Water
Consumption
90/32.2 Air Temperature
Around Ice Machine
Water Temperature °F/°C
50/10.0
70/21.1
90/32.2
Gal/24 hours
220
490
3700
Water regulating valve set to maintain 230 PSIG discharge pressure
Air Temp.
Around Ice
Machine
°F/°C
Freeze Cycle
Harvest Cycle
Discharg
e
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
50/10.0
225-235
60-32
150-170
85-100
70/21.1
225-235
60-33
150-170
85-105
80/26.7
225-240
65-36
155-175
90-110
90/32.2
225-240
68-38
155-175
90-110
100/37.8
235-260
75-40
175-200
100-120
110/43.3
240-265
85-40
185-205
105-125
Suction pressure drops gradually throughout the freeze cycle
Summary of Contents for QD0202A
Page 3: ......
Page 14: ...General Information Section 1 1 4 Part No 80 1100 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 34: ...Installation Instructions Section 2 2 20 Part No 80 1100 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 50: ...Maintenance Section 3 3 16 Part No 80 1100 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 93: ...Section 6 Electrical System Part No 80 1100 3 6 37 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 112: ...Electrical System Section 6 6 56 Part No 80 1100 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 135: ...Section 7 Refrigeration System Part No 80 1100 3 7 23 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 168: ...Refrigeration System Section 7 7 56 Part No 80 1100 3 Figure 7 18 Using Pinch Off Tool SV1406 ...
Page 174: ...Refrigeration System Section 7 7 62 Part No 80 1100 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 175: ...Section 7 Refrigeration System Part No 80 1100 3 7 63 THIS PAGE INTENTIONALLY LEFT BLANK ...