Section 7
Refrigeration System
Part No. 80-1100-3
7-19
Freeze Cycle Suction Pressure High Checklist
Freeze Cycle Suction Pressure Low Checklist
NOTE: Do not limit your diagnosis to only the items
listed in the checklists.
Possible Cause
Check/Correct
Improper installation
See “Installation/Visual Inspection Checklist” on
Page 7-10
Discharge pressure
Discharge pressure is too high, and is affecting low side
(See “Freeze Cycle Discharge Pressure High Checklist” on
Page 7-16
)
Improper refrigerant charge
Overcharged
Wrong type of refrigerant
Other
Non-Manitowoc components in system
H.P.R. solenoid leaking
harvest valve stuck open
TXV flooding (check bulb mounting)
Defective compressor
Possible Cause
Check/Correct
Improper installation
See “Installation/Visual Inspection Checklist” on
Page 7-10
Discharge pressure
Discharge pressure is too low, and is affecting low side
(See “Freeze Cycle Discharge Pressure Low Checklist” on
Page 7-16
)
Improper refrigerant charge
Undercharged
Wrong type of refrigerant
Other
Non-Manitowoc components in system
Improper water supply over evaporator (See “Water System Checklist” on page 7-10)
Loss of heat transfer from tubing on back side of evaporator
Restricted/plugged liquid line drier
Restricted/plugged tubing in suction side of refrigeration system
TXV starving
Summary of Contents for QD0202A
Page 3: ......
Page 14: ...General Information Section 1 1 4 Part No 80 1100 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 34: ...Installation Instructions Section 2 2 20 Part No 80 1100 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 50: ...Maintenance Section 3 3 16 Part No 80 1100 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 93: ...Section 6 Electrical System Part No 80 1100 3 6 37 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 112: ...Electrical System Section 6 6 56 Part No 80 1100 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 135: ...Section 7 Refrigeration System Part No 80 1100 3 7 23 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 168: ...Refrigeration System Section 7 7 56 Part No 80 1100 3 Figure 7 18 Using Pinch Off Tool SV1406 ...
Page 174: ...Refrigeration System Section 7 7 62 Part No 80 1100 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 175: ...Section 7 Refrigeration System Part No 80 1100 3 7 63 THIS PAGE INTENTIONALLY LEFT BLANK ...