M A G U I R E P R O D U C T S , I N C .
64
W E I G H S C A L E B L E N D E R
RNC 00050
Allowable GRAM error within which NO correction is made.
NNC 00050
CNC 00010
ANC 00010
This is the acceptable error range for each component to prevent hunting. They adjust automatically over an
extended time period to match the flow characteristics of each material.
RRP 00010
PERCENT shortage error that will force a retry.
NRP 00010
CRP 00010
ARP 00010
RRD 00500
GRAM weight shortage error that will force a retry.
NRD 00500
CRD 00050
ARD 00050
Both RP and RD limits must be met before system will advance to the next component. Retries occur until both
conditions are met.
RLA 00020
Lag TIME before dumping ACTUALLY starts.
NLA 00020
(mechanical response time, interrupts)
CLA 00012
ALA 00012
These parameters state the lag time between when a device is signaled and when it actually begins to operate.
Change ONLY if you change to non-standard equipment.
PRC 00010
MAX. PERCENTAGE CHANGE - Maximum allowable PERCENT rate change per cycle.
This prevents excessive swings in flow rates by the software. Do not change.
STL 00122
DISPENSE SETTLE TIME before a weight reading is taken.
The time (interrupts) allowed for material to SETTLE in the weigh bin before a weight is taken. Lengthen only to
slow the next cycle start, thereby lowering the pile of material in the mix chamber, and, in some cases, improving
mixing.
LCL 00027
LOAD CELL limits, low slope, high slope, frequency, zero.
LCH 00039
DO NOT CHANGE except for different weight load cells.
LCF 00079
The above 4 parameters relate to the characteristics of the LOAD CELLS on your blender.
LCZ 00583
DO NOT CHANGE THEM.
SCR 00000
Special Customer Request function to be activated.
BCR 00000
For BAR CODE input equipped blenders.
The following parameters are all related to EXTRUSION CONTROL only.
XTP 05050
Extrusion Control - TRIP POINT for a Rate adjustment.
As batch timing errors accumulate, this number determines how large the accumulated error
must be to force an adjustment.
XCV 00000
Extrusion Control - Extruder speed Control Voltage.
XRC 00004
Extrusion Control - Extruder speed Rate of Change.
These two parameters control the voltage output to the extruder speed control, and its rate of change.
TCV 00000
Extrusion Control - Takeoff speed control voltage.
TRC 00004
Extrusion Control - Takeoff speed Rate of Change.
These two parameters control the voltage output to the downstream
takeoff speed control, and its rate of change.
XAL 00005
Extrusion Control - Single Adjustment Limit, percent.
Single rate adjustments are limited to this percentage change.
XUL 00200
Extrusion Control - Upper Adjustment Limit, volts
Summary of Contents for Weigh Scale Blender
Page 17: ...M A G U I R E P R O D U C T S I N C 17 W E I G H S C A L E B L E N D E R...
Page 116: ...M A G U I R E P R O D U C T S I N C 116 W E I G H S C A L E B L E N D E R Technical Drawings...
Page 117: ...M A G U I R E P R O D U C T S I N C 117 W E I G H S C A L E B L E N D E R...
Page 118: ...M A G U I R E P R O D U C T S I N C 118 W E I G H S C A L E B L E N D E R...
Page 119: ...M A G U I R E P R O D U C T S I N C 119 W E I G H S C A L E B L E N D E R...
Page 120: ...M A G U I R E P R O D U C T S I N C 120 W E I G H S C A L E B L E N D E R...
Page 121: ...M A G U I R E P R O D U C T S I N C 121 W E I G H S C A L E B L E N D E R...
Page 122: ...M A G U I R E P R O D U C T S I N C 122 W E I G H S C A L E B L E N D E R...
Page 123: ...M A G U I R E P R O D U C T S I N C 123 W E I G H S C A L E B L E N D E R...
Page 124: ...M A G U I R E P R O D U C T S I N C 124 W E I G H S C A L E B L E N D E R...
Page 125: ...M A G U I R E P R O D U C T S I N C 125 W E I G H S C A L E B L E N D E R...
Page 126: ...M A G U I R E P R O D U C T S I N C 126 W E I G H S C A L E B L E N D E R...
Page 127: ...M A G U I R E P R O D U C T S I N C 127 W E I G H S C A L E B L E N D E R...
Page 136: ...M A G U I R E P R O D U C T S I N C 136 W E I G H S C A L E B L E N D E R...