MT-95 RS-232 HiCo/LoCo Encoder/Reader
10
Table 2-1. Default Parameters
Parameter Description
Baud rate
9600
Parity Even
Data Bits
7 (Even or Odd parity is always 7 bits; no parity is
always 8 bits)
Stop Bits
1
Coercivity
Auto - When a card is encoded, the program
automatically selects High or Low coercivity
Tracks
1, 2, and 3 are enabled
4. When
Enter
is pressed, the LCD will display:
Select online data parity
Enter=done
N)one[8 bit] O)dd[7 bit] E)ven[7 bit]
Press
N
,
O
, or
E
to highlight the parity setting and
Enter
to select it. The default is odd.
If
Esc
is pressed, the original parity value will remain in effect.
5.
The next display is:
Select online stop bits
Enter=done
1)Stop bit
2)Stop bits
Press
1
or
2
to
highlight the stop bits setting and
Enter
to select. The default is 1. If
Esc
is pressed, the original stop bit setting will remain in effect.
6. When
Enter
is pressed, the program will return to the following display:
Select option to change
Esc=exit
T)racks S)erial E)ncode M)ode C)ard Time
Type
E
and the display will be:
Select encode coercivity
Enter=done
H)igh
L)ow
A)uto
A HiCo card is harder to erase than a LoCo card, which can be erased by a small magnet.
Auto is a Mag-Tek proprietary encoding technique that determines if the card is HiCo or
LoCo.
Summary of Contents for MT-95
Page 7: ...vii...
Page 8: ...viii Figure 1 1 MT 95 Encoder Reader...
Page 12: ...MT 95 RS 232 HiCo LoCo Encoder Reader 4 Figure 1 2 Encoder Parts and Card Orientation...
Page 22: ...MT 95 RS 232 HiCo LoCo Encoder Reader 14...
Page 34: ...MT 95 RS 232 HiCo LoCo Encoder Reader 26...
Page 44: ...MT 95 RS 232 HiCo LoCo Encoder Reader 36...
Page 50: ...MT 95 RS 232 HiCo LoCo Encoder Reader 42...