Section 5. Online Programming
31
The commands are as follows:
Note
All commands are case insensitive.
Change Encode Coercivity Mode
/L
= switch to LoCo only mode
/H
= switch to HiCo only mode
/A
= switch to Automatic selection mode
Change Online Encode Mode
/S
= Secure mode on (the Encoder must do a good read before it will accept an
encode
command)
/N
=
Normal mode - Secure mode off (the Encoder can do an encode at any time)
Change Configuration
/K
= read/encode capability in standalone mode with a keyboard
/X
= keyboard can be used only for setup – no read/encode capability is allowed
/V
= request version – Response is:
<CR><LF>P/N:30060819<SP><SP>Rev.D01<CR><LF>
/Dn
= where n=1, 2, or 3 – Disable a track
/En
= where n=1, 2, or 3 – Enabler a track
/T
= request current track setup. Format is “Enable Tracks: 1 2 3” where 1 2 3 are
sent if the track is enabled or omitted if the track is disabled. A return/line
feed pair is sent to terminate the response.
/C
=
request MT-95 configuration
Abort
/Q
=
Send to the MT-95 to abort from the encode mode.
Operation
/B
=
Sound the buzzer on the MT-95. This can be used to alert the user.
/P
=
Request card position. This can be used to see if a card is in the slot. The
following table shows the position indications:
Value Card
Position
0
No card is in slot
1
Card is stopped on right side of slot
2
Card is stopped on left side of slot
3
Card is near right side of the slot
4
Card is near write head
5
Card is near left side of slot
6
Card is moving near read head
7
Two cards in slot
Summary of Contents for MT-95
Page 7: ...vii...
Page 8: ...viii Figure 1 1 MT 95 Encoder Reader...
Page 12: ...MT 95 RS 232 HiCo LoCo Encoder Reader 4 Figure 1 2 Encoder Parts and Card Orientation...
Page 22: ...MT 95 RS 232 HiCo LoCo Encoder Reader 14...
Page 34: ...MT 95 RS 232 HiCo LoCo Encoder Reader 26...
Page 44: ...MT 95 RS 232 HiCo LoCo Encoder Reader 36...
Page 50: ...MT 95 RS 232 HiCo LoCo Encoder Reader 42...