MIG 200L PRO DUAL PULSE
24
TROUBLE SHOOTING
Malfunctions
Solution
Burn back
Adjust the voltage selection to minor 5%-10%, try until welding
normally. Then you can adjust the wire feeding speed as you want.
The meter show nothing;
Fan does not rotate;
No welding output
Confirm the power switch is on.
Power supply available for input cable.
Check if the three phase commute bridge is damaged.
There is malfunction occurs in the supplementary power source on
control board (contact dealers).
The meter shows;
Fan works normally;
No welding output
Check if all the sockets in the machine are connected well.
There is open circuit or badness of connect at the joint of output
terminal.
The control cable on the torch is broken off or the switch is
damaged.
The control circuit is damaged.(contact to dealers)
the meter shows;
Fan works normally;
Abnormal indicator lights.
It might be over-current protection, please turn off the power
switch; restart the machine after the abnormal indicator light
winked.
It might be overheating protection, please wait for about 2-3
minutes until the machine renew without turn off the power switch.
It might be multifunction of inverter circuit. (contact dealers)
Power indicator light is not on, fan
does not turn, no welding press
output
Power switch is broken
Verify that the electrical grid connected to the input
electromechanical regulations has electricity
Enter whether there is a break in the cable