2.0 Installation
© 2012 Magnum Energy, Inc.
8
Figure 2-6, Connecting the AGS to a Magnum Inverter (Large)
Large Magnum inverter
ME-AGS-N
Network Communications
cable from AGS NETWORK
(green) port to inverters
Network (green) port
Remote cable to
inverters Remote
(blue) port
Remote
DC 12.6V 5A
Figure 2-5, Connecting the AGS to a Magnum Inverter (Small)
Remote
ME-AGS-N
Small Magnum inverter
Phone splitter that connects
AGS network cable (from
AGSs green NETWORK port)
and remotes cable to
inverters Remote (blue) port
DC 12.6V 5A
Connecting the AGS to a Magnum inverter:
Connect one end of the
communication cable to the AGSs RJ14 NETWORK (green) port, and then:
• Small inverter (MM/MMS Series)
connect the other end of the
communication cable to a phone splitter, and then connect the splitter
to the REMOTE (blue) port on the small Magnum inverter (see Figure
2-5); or,
• Large inverter (ME, RD, MS, MS-PAE Series)
connect the other
end of the communication cable to the RJ14 Network port (green) on the
large Magnum inverter (see Figure 2-6).