Swing Door
MPS-122
Malfunctions
81
Error code
Fault description
Automatic reset
60
Error when initialising CAN protocol stack
No
61
Error when initialising CAN bus
No
62
CAN servo address fault
No
63
Error download of controller parameters for the MMC-120
No
64 Reserved
No
65 Error
I²C-EEPROM No
66
Software fault
No
70 to 7F
Error when downloading the MMC-120 firmware
No
Table 8: Error code
Self-resetting errors are displayed for no more than 20 seconds if
the error is no longer pending. The error code is shown, however,
as long as the error is pending.
The swing door is taken out of operation in case of errors that are
not self-resetting. The error code is displayed continually until the
control is taken into operation again after removal of the error.