Swing Door
MPS-122
Setting swing door parameters – "MPS-Diag"
63
10.4.6 Set hold-open time
The "hold-open time" parameter is used to set the hold-open time
between 0 and 25 seconds in steps of 100 ms. Entering 50 means
5 seconds.
Fig. 34: Set hold-open time
10.4.7 Set
speed
The parameter "Speed" sets one of the three specified speeds "0
(slow)", "1 (medium)" or "2" (fast). The speed applies to regular
operation.
If you have chosen "more than 1.3 m" for the parameter "U-bar
size", the parameter "Speed" only has the option "0 (slow)".
Observe that you always have to choose "above 1.3 m" for glass
wings.
→
For the parameter "U-bar size", see page 62,
chapter 10.4.3.
Fig. 35: Set speed
10.4.8 Heating active while standing
This option is used to determine if heating is activated while
standing. The heating is needed if the swing door is used at
ambient conditions below 0°C.
Fig. 36: Switch on standing heating.