Swing Door
MPS-122
Setting swing door parameters – "MPS-Diag"
60
10.4 Function and parameter settings
Function and parameter settings are made through the Windows
programme MPS-Diag.
The following functions can be set:
Design left / right
Brake activated / not activated in the three positions, in case of
vandalism or when pressed in the wrong direction
Present locking element size
Reset source
Behaviour when obstruction detected
Hold-open time
Speeds
Heating active while standing
Programming the two end positions and the home position
Resetting all parameters to factory settings
10.4.1 Version left / right
This selection point informs the control whether it is a right or a left
version of the swing door. In the "right" version, the locking bracket
swivels against the right mechanical end stop when homing. In the
"left" version, the locking bracket swivels against the right
mechanical end stop when homing.
Fig. 28: Explanation on version "Right" and "Left",
here the directions for the left swing door are presented