Barrier MHTM
TM
MicroDrive
Electrical connection
92
5815,5001US / Version 02.66
DANGER!
Mortal danger by electric voltage!
1. Disconnect barrier system power supply. Ensure that the
system is powered down. Secure against reactivation.
Strip-off cable and core insulation –
preparation of the wiring
2. Strip-off mains supply and cores according to the following
figure.
Mag00201
0.79
(20)
0.31
(8)
1.18
(30)
0.31
(8)
2
3
1
Fig. 38: Strip-off the mains supply
Dimensions in inch or feet are without parenthesis. Dimensions in
mm are in parenthesis
1 Phase
2 Neutral
conductor
3 Ground
conductor
Mains supply placement
3. Connect mains supply to the provided terminal clamps
(X1: L/N/PE) of the barrier housing according to the following
figures.
See also page 181, chapter 18.1.
Place mains supply properly in the barrier housing. The line
must be wired so that no damage could occur due to
moving parts.
Attach mains supply to the metal tabs via 2 cable ties.
1
Fig. 39: Mains supply placement
1 Mains
supply
2 Cable
tie
3
Cable tie metal tabs
Summary of Contents for MHTM MicroDrive
Page 1: ...Operating Instructions Barrier MHTMTM MicroDrive Doc ID 5815 5001US Version 02 6...
Page 4: ...Barrier MHTM TM MicroDrive 4 5815 5001US Version 02 66...
Page 10: ...Barrier MHTM TM MicroDrive 10 5815 5001US Version 02 66...
Page 178: ...Barrier MHTM TM MicroDrive 178 5815 5001US Version 02 66...
Page 179: ......
Page 180: ...Barrier MHTM TM MicroDrive 180 5815 5001US Version 02 66...
Page 182: ...Barrier MHTM TM MicroDrive Appendix 182 5815 5001US Version 02 66...
Page 184: ......
Page 186: ......
Page 188: ......
Page 195: ...Barrier MHTM TM MicroDrive 5815 5001US Version 02 6 195...