Barrier MHTM
TM
MicroDrive
Parameterising control unit
116
5815,5001US / Version 02.66
10.7.4
Mode 4: Two-Pulse control (bistable)
Typical application
This mode is suitable for barriers on factory premises, etc. that are
often frequented by vehicles. The barrier must be operated by a
person.
Function
The barrier is opened and closed completely via two separate
command units (signal). One pulse on the respective input is
sufficient for opening or closing. The pulse must be present
between 100 and 300 ms.
The input function "Open high priority" is superordinated to the
input function "Close". This means that while a closing signal is
applied, the barrier can be opened by the signal “Open high
priority”. When the opening signal is removed, the barrier closes
again at once after opening completely.
Supported input functions
Input function
Signal type
Supported/
Not supported
Open low priority
Pulse or
permanent signal
Supported
Open low priority with
vend count
Pulse signal
Supported
Open high priority
Pulse or
permanent signal
Supported
Opening loop
–
Not supported
Close
Pulse or
permanent signal
Supported
Table 38: Supported input functions "Two-Pulse control"
See page 97, chapter 9.4.6 "Digital inputs".
Summary of Contents for MHTM MicroDrive
Page 1: ...Operating Instructions Barrier MHTMTM MicroDrive Doc ID 5815 5001US Version 02 6...
Page 4: ...Barrier MHTM TM MicroDrive 4 5815 5001US Version 02 66...
Page 10: ...Barrier MHTM TM MicroDrive 10 5815 5001US Version 02 66...
Page 178: ...Barrier MHTM TM MicroDrive 178 5815 5001US Version 02 66...
Page 179: ......
Page 180: ...Barrier MHTM TM MicroDrive 180 5815 5001US Version 02 66...
Page 182: ...Barrier MHTM TM MicroDrive Appendix 182 5815 5001US Version 02 66...
Page 184: ......
Page 186: ......
Page 188: ......
Page 195: ...Barrier MHTM TM MicroDrive 5815 5001US Version 02 6 195...