Barrier MHTM
TM
MicroDrive
Assembly and installation
64
5815,5001US / Version 02.66
2. Lay the loop carefully into the groove and push it down by
means of a blunt object, such as a piece of wood. The
insulation must by no means be damaged.
3. To avoid slipping of the loop, fix the loop using small wooden
wedges. Remove the wooden wedges later on.
4. Push the loop feed line through the empty conduit in place into
the barrier housing.
5. Measure the induction loop according to chapter 8.4.3.
6. We recommend to cover the inserted loop using quartz sand.
Make sure that at least 0.98 in (25 mm) remain between the
upper edge of the roadway and the quartz sand for the potting
compound.
7. Seal the groove with the potting compound.
The temperature resistance of the loop must match the
temperature of the potting compound.
8. Allow the potting compound to cure.
S0104a
3
1
2
4
5
6
11.8
(300)
5.91
(150)
1.97
(50)
1.18
(30)
0.98
(25)
Fig. 20: Installing induction loop in bitumen, asphalt, or concrete
Dimensions in inch are without parenthesis. Dimensions in mm
are in parenthesis.
1 Barrier
housing
2
Groove with potting compound
3 Asphalt
surface
4
Quartz sand filling
5 Loop
cable
6 Foundation
Summary of Contents for MHTM MicroDrive
Page 1: ...Operating Instructions Barrier MHTMTM MicroDrive Doc ID 5815 5001US Version 02 6...
Page 4: ...Barrier MHTM TM MicroDrive 4 5815 5001US Version 02 66...
Page 10: ...Barrier MHTM TM MicroDrive 10 5815 5001US Version 02 66...
Page 178: ...Barrier MHTM TM MicroDrive 178 5815 5001US Version 02 66...
Page 179: ......
Page 180: ...Barrier MHTM TM MicroDrive 180 5815 5001US Version 02 66...
Page 182: ...Barrier MHTM TM MicroDrive Appendix 182 5815 5001US Version 02 66...
Page 184: ......
Page 186: ......
Page 188: ......
Page 195: ...Barrier MHTM TM MicroDrive 5815 5001US Version 02 6 195...