![Magnetic Autocontrol MHTM MicroDrive Access Series Operating Instructions Manual Download Page 90](http://html1.mh-extra.com/html/magnetic-autocontrol/mhtm-microdrive-access-series/mhtm-microdrive-access-series_operating-instructions-manual_3583810090.webp)
Barrier MHTM
TM
MicroDrive Access and Parking
Electrical connection
90
5815,5013US / Version 05
9.4.2
Plausibility check of the safety devices
NOTE!
The plausibility check is deactivated by default in
barriers in Deadman operation at a closing speed
of
≥
2.2 seconds.
The plausibility check prevents that the barrier can be operated
without safety device or with defective safety device.
When the power supply is switched on, it is verified that at least
one safety device was passed by a vehicle or person within three
barrier openings. In operation, the number is increased to ten
barrier openings.
If the plausibility check fails, the barrier is decommissioned for
reasons of safety. The message "Safety device missing" appears
on the display.
NOTE!
The input function "Additional safety device" must
only be used for additional monitoring devices. The
input function is not considered in the plausibility
check. A safety loop always has to be connected to
the detector module or a testable safety light
barrier at the clamps X11 and X20.
Procedure at failed plausibility
check
1. Remove cause for failed plausibility check.
2. Reset the barrier.
→
Summary of Contents for MHTM MicroDrive Access Series
Page 4: ...Barrier MHTM TM MicroDrive Access and Parking 4 5815 5013US Version 05...
Page 126: ...Barrier MHTM TM MicroDrive Access and Parking 126 5815 5013US Version 05...
Page 129: ......
Page 130: ...Barrier MHTM TM MicroDrive Access and Parking 130 5815 5013US Version 05...
Page 132: ...Barrier MHTM TM MicroDrive Access and Parking Appendix 132 5815 5013US Version 05...
Page 134: ......
Page 136: ......
Page 138: ......
Page 140: ......