![Magnetic Autocontrol MHTM MicroDrive Access Series Operating Instructions Manual Download Page 108](http://html1.mh-extra.com/html/magnetic-autocontrol/mhtm-microdrive-access-series/mhtm-microdrive-access-series_operating-instructions-manual_3583810108.webp)
Barrier MHTM
TM
MicroDrive Access and Parking
Malfunctions
108
5815,5013US / Version 05
Malfunction:
Barrier does not open.
Possible cause
Corrective action
Removal by
Power supply is not connected
Switch on power supply.
Check power supply.
Electrical specialist
Error present. The corresponding
error message is displayed.
Depending on error message, check
components, wiring, etc.
MHTM MicroDrive
service specialist
Power supply is present. Control unit
display does not light up.
Control unit defective. Replace the
control unit. Contact service.
MHTM MicroDrive
service specialist
Closing signal is active.
Remove closing signal
Electrical specialist
Too high trigger sensitivity set for the
loop.
Check the response sensitivity of the
loop and adjust if necessary.
MHTM MicroDrive
service specialist
Malfunction:
Barrier does not open completely.
Possible cause
Corrective action
Removal by
Spring tension in the balancing
springs of the lever system set too
weakly for the barrier arm weight.
Adjust balancing springs.
→
MHTM MicroDrive
service specialist
Malfunction:
Barrier does not close. The message "Waiting for
release" appears on the display.
Possible cause
Corrective action
Removal by
The message appears after the
power supply is switched on, after
voltage returns and after reset.
The release signal can be given by
an external closing signal or by
pushing the left operating button at
the control unit.
→
See separate
document "Description of control
units MGC and MGC Pro for MHTM
TM
MicroDrive barriers", chapter "Start-
up settings".
Operator
Malfunction:
Barrier does not close. The message "Waiting for
passage" appears on the display.
Possible cause
Corrective action
Removal by
The message appears after the
power supply is switched on, after
voltage returns and after reset.
The barrier closes once a vehicle
passes.
→
See separate
document "Description of control
units MGC and MGC Pro for
MHTM
TM
MicroDrive barriers",
chapter "Start-up settings".
Confirm message with the left
button at the control unit.
Operator
Summary of Contents for MHTM MicroDrive Access Series
Page 4: ...Barrier MHTM TM MicroDrive Access and Parking 4 5815 5013US Version 05...
Page 126: ...Barrier MHTM TM MicroDrive Access and Parking 126 5815 5013US Version 05...
Page 129: ......
Page 130: ...Barrier MHTM TM MicroDrive Access and Parking 130 5815 5013US Version 05...
Page 132: ...Barrier MHTM TM MicroDrive Access and Parking Appendix 132 5815 5013US Version 05...
Page 134: ......
Page 136: ......
Page 138: ......
Page 140: ......