Please observe following points when installing the induction loop:
Loop geometry and clearances
Install the loop symmetrically to the barrier arm. Please make
sure that the barrier arm is attached to the side of the barrier
housing.
The clearance of the safety loop for passenger cars in front of,
and behind the barrier arm must be at least 19.7 in (500 mm).
The safety loop for trucks must be dimensioned larger.
→
See
page 29, Fig. 4 to page 35, Fig. 6.
The distance of the induction loop from the roadside should be
about 11.8 in to 19.7 in (300 to 500 mm).
Install opening loops right in front of the safety loop. The
clearance between opening loop and safety loop must be not
greater than 3.28 ft (1 m) for trucks and passenger cars.
If there are iron reinforcements, ramp heating etc. in the
roadway, the induction loop must have a clearance of at least
1.97 in (50 mm) from those. Metals in the proximity of the
induction loop affect the response sensitivity.
Avoid direct contact of induction loops with reinforcement and
ramp heating.
Install induction loops with sufficient clearance from sliding
gates, roller grilles etc.
Installation and ground conditions
Please make sure when moulding or installing that the loop can
not move anymore once it is in operation. Any geometric
alteration will act as inductance change, which will set the
detector to an error state.
Brittle road surfaces, loose pavements, gravel paths etc. are not
suited for the application of induction loops.
Feed line
The feed line to the loop must not exceed 49.2 ft (15 m).
The loop connection cable must protrude about 4.9 ft (1.5) m
from the foundation.
Shorten the feed line to the loop to the proper length. The feed
line must by no means be coiled.
The feed line must be twisted up to right in front of the terminals
of the loop detector with ca. 6 twists per feet.
Summary of Contents for MHTM MicroDrive Access Series
Page 4: ...Barrier MHTM TM MicroDrive Access and Parking 4 5815 5013US Version 05...
Page 126: ...Barrier MHTM TM MicroDrive Access and Parking 126 5815 5013US Version 05...
Page 129: ......
Page 130: ...Barrier MHTM TM MicroDrive Access and Parking 130 5815 5013US Version 05...
Page 132: ...Barrier MHTM TM MicroDrive Access and Parking Appendix 132 5815 5013US Version 05...
Page 134: ......
Page 136: ......
Page 138: ......
Page 140: ......