![Magnetic Autocontrol MHTM MicroDrive Access Series Operating Instructions Manual Download Page 100](http://html1.mh-extra.com/html/magnetic-autocontrol/mhtm-microdrive-access-series/mhtm-microdrive-access-series_operating-instructions-manual_3583810100.webp)
Barrier MHTM
TM
MicroDrive Access and Parking
Start-up and operation
100
5815,5013US / Version 05
Switching off
1. Remove the barrier housing hood.
2. Remove the barrier housing door.
3. Switch off the barrier via the double pole mains switch.
4. Depending on the settings of the lever system's balancing
spring and the settings in the menu "Power failure", the barrier
boom opens or closes.
→
See separate document
"Description of control units MGC and MGC Pro for MHTM
TM
MicroDrive barriers", chapter "Power failure".
5. Mount the door.
6. Attach and lock the hood.
10.4 Opening and closing the barrier manually
You can only open and close the barrier manually in the "Service"
mode.
Fig. 45: Service switch
1
Mode "Service" on
2
Mode "Service" off
1. Switch the "Service" switch for the "Service" mode. The LED
lights red. The display backlighting flashes.
2. Perform one of the following functions:
Push middle left button : Manually open the barrier.
Push middle right button : Manually close the barrier.
3. Switch "Service" switch. The LED must light green.
NOTE!
For reasons of safety, the first barrier arm motion
after switching between programme mode and
service mode is performed at slow speed.
Summary of Contents for MHTM MicroDrive Access Series
Page 4: ...Barrier MHTM TM MicroDrive Access and Parking 4 5815 5013US Version 05...
Page 126: ...Barrier MHTM TM MicroDrive Access and Parking 126 5815 5013US Version 05...
Page 129: ......
Page 130: ...Barrier MHTM TM MicroDrive Access and Parking 130 5815 5013US Version 05...
Page 132: ...Barrier MHTM TM MicroDrive Access and Parking Appendix 132 5815 5013US Version 05...
Page 134: ......
Page 136: ......
Page 138: ......
Page 140: ......