background image

Summary of Contents for MG10A-P1

Page 1: ...trictly follow them Keep the manual for future references Lesen Sie die ganze Anleitung vor dem Betrieb aufmerksam durch und folgen Sie beim Betrieb des Ger ts den Anweisungen Bewahren Sie diese Bedie...

Page 2: ......

Page 3: ...J 1 MG10A P1 MG10A P2...

Page 4: ...2 J MG10A P1 MG10A P2 DC AC...

Page 5: ...5 4 1 21 5 4 2 22 6 25 6 1 RS 232C 26 6 1 1 RS 232C 26 6 1 2 26 6 1 3 27 6 1 4 28 6 1 5 29 6 2 I O 31 6 2 1 I O 31 6 2 2 32 6 2 3 33 1 1 1 1 1 1 2 2 1 3 3 2 4 3 6 3 1 6 3 2 I F 7 3 3 DIN 9 3 4 10 3 5...

Page 6: ...ii J MG10A P1 MG10A P2 Microsoft Windows Windows 7 34 8 35 8 1 35 8 2 36 8 3 36 9 37...

Page 7: ...1 MG10A P1 MG10A P2 1 MG10A I F RS 232C I O 1 1 16 I F 1 16 64 1 RS 232C DK DG B DL B BR DT 1 1 DIN 35 mm DIN 1 16 64 DK DG B DL B BR DT 0 1 m 0 5 m 1 m 5 m 10 m P P 4 P P 2 RS 232C BCD BCD DC 12 24...

Page 8: ...2 J MG10A P1 MG10A P2 1 2 MG10A P1 MG10A P2 MG20A DK DK MG20A DG DG B DL B BR MG20A DT DT I F BCD MG30 B1 MG30 B2 RS 232C DZ252 MG10A RS 232C LZ61 CE08 I F...

Page 9: ...J 3 MG10A P1 MG10A P2 1 3 BCD DG DT DL DK PLC 16 RS 232C...

Page 10: ...4 J MG10A P1 MG10A P2 2 6 7 4 5 8 2 9 10 11 12 13 14 1 3...

Page 11: ...J 5 MG10A P1 MG10A P2 RS 232C PLC RS 232C DZ252 LZ61 LZ61 I F I F DIN DIN 0 F RS 232C RS 232C I O PLC I O DC 12 V 24 V...

Page 12: ...6 J MG10A P1 MG10A P2 3 3 1 16 1 2...

Page 13: ...J 7 MG10A P1 MG10A P2 2 3 1 1 4 3 4 3 2 I F I F 1 1...

Page 14: ...8 J MG10A P1 MG10A P2 I F I F 2 1 3 3...

Page 15: ...J 9 MG10A P1 MG10A P2 DIN DIN DIN 2 3 3 DIN DIN DIN 35 mm DIN 1...

Page 16: ...10 J MG10A P1 MG10A P2 3 5 3 I O 3 GND 2 Vin DC 12 V 24 V 1 FG 3 1 2 3 4 1...

Page 17: ...J 11 MG10A P1 MG10A P2 3 6 LZ61 CE08 1 3 7 RS 232C DZ252 RS 232C RS 232C I F 1...

Page 18: ...12 J MG10A P1 MG10A P2 4 2 5 6 4 2 1 MG10A 4 2 2 2 2 4 RS 232C 5 6 4 1 MAX MIN P P Peak to Peak MAX MIN P P P P P P...

Page 19: ...J 13 MG10A P1 MG10A P2 4 2 3 DK 1 1 mm 1 mm 2 3...

Page 20: ...14 J MG10A P1 MG10A P2 4 2 5 P P RS 232C SETUP P CLOSE 1 mm RS 232C 1 4 2 4 0 4...

Page 21: ...J 15 MG10A P1 MG10A P2 4 2 6 RS 232C MG30 B BCD 4 RS 232 NG U GO G GO G GO G NG L...

Page 22: ...16 J MG10A P1 MG10A P2 ON P P OFF 4 2 7...

Page 23: ...J 17 MG10A P1 MG10A P2 5 OFF 5 1 RS 232C 5 4 0 1 0 1 4 0 1 4 RS 232C RS 232C 3 6 1 3 RS 232C RS 232C 5 2 9600 bps 8 bit 1 bit CR LF RTS CTS...

Page 24: ...18 J MG10A P1 MG10A P2 5 2 5 2 1 0 F 1...

Page 25: ...OFF 7 bit ON bit SW 5 1 bit OFF 2 bit ON SW 3 SW 4 OFF OFF OFF ON Even ON OFF ON Odd ON ON SW 2 CR LF OFF CR ON SW 1 OFF ON 5 2 2 RS 232C RS 232C SW1 RS TRG SW 7 SW 8 2400 bps OFF OFF 9600 bps ON OFF...

Page 26: ...P2 5 3 2 SW 1 ON OFF SW 2 SW 3 SW 4 OFF OFF OFF DK 0 1 m ON OFF OFF 0 1 m DK 0 5 m OFF ON OFF 0 5 m DG B DT512 ON ON OFF 1 m DT12 DT32 OFF OFF ON 5 m DL BR DL310B DL330B ON OFF ON 10 m OFF ON ON ON O...

Page 27: ...J 21 MG10A P1 MG10A P2 5 4 RS 232C RS 232C OFF 6 1 RS 232C 3 5 4 1 SETUP MODE P CH CL SCN REF LCLR STTERM START RSSEP RS 232C RSFORM RS 232C RSTRG RS 232C CLOSE...

Page 28: ...e Return LF Line Feed 2 OFF CR LF ON CR 0 F 0 F 0 F 16 10 0 15 SETUP SETUP MODE MODE MODE 0 REAL 1 MAX 2 MIN 3 P P P P P P P 0 1 m 0 5 m 2 4 99 9999 99 9999 99 9995 99 9995 5 0 1 m 5 m 3 3 999 999 999...

Page 29: ...995 99 9995 5 0 1 m 5 m 3 3 999 999 999 999 999 995 999 995 5 0 10 m 4 2 9999 99 9999 99 SCN SCN SCN 1 1 2 2 3 3 4 4 REF REF REF 0 1 LCLR LCLR LCLR REF 1 STTERM STTERM START STTERM 0 START 1 HOLD LATC...

Page 30: ...4 J MG10A P1 MG10A P2 RSTRG RSTRG RS232C RSTRG 0 RS TRG 1 RS TRG 2 RS TRG 0 2 s 3 RS TRG 0 5 s 4 RS TRG 1 0 s 5 RS TRG 5 0 s 6 RS TRG 10 s 7 RS TRG 30 s 8 RS TRG 60 s 9 RS TRG 300 s RS TRG CLOSE CLOSE...

Page 31: ...J 25 MG10A P1 MG10A P2 6 RS 232C I O I F I F I F 4 2 3 OFF RS 232C I O...

Page 32: ...1 RS 232C EIA RS 232C 2400 9600 19200 38400 bps 7 bit 8 bit odd even 1 bit 2 bit 15 m RTS CTS RS 232C DZ252 No 1 2 3 4 5 6 7 8 8 DIN MG10A DZ252 No 1 2 3 4 5 6 7 8 9 9 Dsub I O 1 N C 2 SG GND 3 I RXD...

Page 33: ...A P2 8 1 0 1 m 99 9999 99 9999 2 10 m 9999 99 9999 99 3 F 99 9999 F0 0000 F0 0001 4 Error E r r o r 1 2 CR LF RS 232C 2 CR LF 1 CR 2 OFF CR LF ON CR 6 1 3 0 1 n 5 1 0 F 2 2 0 F 3 3 N A I P P P 4 4 M m...

Page 34: ...28 J MG10A P1 MG10A P2 6 1 4 6 1 3 PC PLC LZ61 10 m RS 232C SW1 RS TRG 3 1 2 00 09 9999 2 4 00NM 09 9999 3 5 00NMG 09 9999...

Page 35: ...J 29 MG10A P1 MG10A P2 1 CR CR LF CR Carriage Return LF Line Feed 2 OFF CR LF ON CR 0 F 0 F 0 F 16 10 0 15 6 1 5 R r P P P P MAX MIN REAL MODE 5 4 RCL RES START P 5 4 CH 5 4 CL 5 4 SCN 5 4 PAU LCH L...

Page 36: ...30 J MG10A P1 MG10A P2 LCH LCH ON OFF L L LO LO LO 99 9999 99 9999 VER VER VER No 0VER 10 5 4 P P P P P P MAX MAX MIN MIN REAL REAL RCL RCL RES RES START START P P PAU PAU ON OFF...

Page 37: ...J 31 MG10A P1 MG10A P2 I O 7 P1 COM P2 COM 6 O 5 P1 COM P2 COM 4 I 3 I 2 I RS RS 232C RS 232C 1 I 6 2 I O RS 232C I O 7 6 2 1 I O...

Page 38: ...COM VOL 1 4 V IOL 10 mA VOH 26 4 V IOH 50 A MG10A P1 COM COM COM OUT COM OUT IN IN 1 2 k 5 V 24 V 5 V 24 V MG10A P1 1 2 W MG10A P2 MG10A P2 COM COM COM OUT COM OUT IN IN 5 V 24 V MG10A P2 5 V 24 V 1...

Page 39: ...J 33 MG10A P1 MG10A P2 6 2 3 MIN 25 ms MIN 1 ms RS RS MIN 2 ms MAX 2 ms MIN 2 ms RS 232C...

Page 40: ...34 J MG10A P1 MG10A P2 7 I O RS 232C Error 3 5 E 1 00 Error 2 00NM Error 3 00NME Error 2 F 1 00 F0 0000 6 6...

Page 41: ...1 I F RS 232C EIA 232C 2400 9600 19200 38400 bps 7 8 bit 1 2 bit ODD EVEN CR CR LF RTS CTS 16 64 10 m I O P1 COM P2 COM DC5 24 V P1 COM P2 COM DC5 24 V RS MG20A DK MG20A DG MG20A DT 16 1 I F MG30 B1...

Page 42: ...MG10A P2 8 2 I O 7 MC1 5 7 ST 3 5 1 3 MC1 5 3 ST 3 5 1 2 1 1 3 8 3 mm BCD I O 64 5 64 64 5 64 108 5 108 5 33 1 35 65 4 35 23 4 35 20 5 20 5 64 99 105 99 105 99 105 5 64 5 24 5 MG10A P1 MG20A DK MG30 B...

Page 43: ...J 37 MG10A P1 MG10A P2 12 V 24 V RS 232C MG10A MG10A MG10A 9 MG10A...

Page 44: ...38 J MG10A P1 MG10A P2...

Page 45: ...read these Safety Precautions before operating installing maintaining inspecting repairing or otherwise working on this unit Warning Indication Meanings The following indications are used throughout...

Page 46: ...ese actions may also damage the internal circuitry This device operates with DC power supply Absolutely do not connect an AC power supply to the terminals as this may result in fire or electrical shoc...

Page 47: ...mat 27 6 1 4 Link Connection 28 6 1 5 Operation Commands 29 6 2 I O Connector 31 6 2 1 I O Connector Pin Assignment 31 6 2 2 Input Output Circuits 32 6 2 3 Signal Timing 33 1 Overview 1 1 1 Features 1...

Page 48: ...in the manual Other system names product and service names described in the instruction manual are trademarks or registered trademarks of their corresponding manufacturers 7 Alarm Display Output 34 8...

Page 49: ...de an electrical parts panel Construction that allows for installation on DIN rails 35 mm DIN rail Expansion from 1 to 16 channels enabled by module configuration Connection of up to 64 channels possi...

Page 50: ...DK series sold separately MG20A DG For DG B DL B BR series MG20A DT For DT series I F module BCD module MG30 B1 Photocoupler insulated open sold separately collector output current sink type MG30 B2...

Page 51: ...E 3 MG10A P1 MG10A P2 1 3 System Configuration Computer Measuring unit BCD DG Series DT Series DL Series DK Series PLC Link Max 16 units RS 232C judgment Go No Go...

Page 52: ...4 E MG10A P1 MG10A P2 6 7 4 5 8 2 9 10 11 12 13 14 1 3 2 Name and Function of Each Part...

Page 53: ...This is connected to the I F module m Slide locks Secures a module which has been connected n DIN rail anchoring lever Secures the main unit to the DIN rails a POWER lamp Lights green when the power...

Page 54: ...be mixed and used in accordance with the application Up to 16 counter modules can be connected Remove the rubber cover installed over the counter module connector on the right side panel of the main m...

Page 55: ...or which was installed last When removing the connected counter modules Follow steps 1 to 4 above in reverse Before removing the modules do not forget to release the slide locks 3 4 3 2 Connecting the...

Page 56: ...nto the main module so that the I F module connectors are aligned properly 2 Secure the I F module using the top and bottom slide locks When removing the connected I F module Follow steps 1 to 3 above...

Page 57: ...panel with the top of the DIN rails 1 Install the unit by pushing it into position until a clicking sound is heard so that the bottom side of the groove in the unit s rear panel fits snugly on the DIN...

Page 58: ...counter module Connecting the wrong measuring unit can cause a breakdown of the connector 1 3 5 Connecting the Power Connector Wire the accessory 3 pin connector to the external power supply No I O Si...

Page 59: ...If the link cable is not long enough use the CE08 extension cable sold separately to extend it Note The multi interface unit will not work if the LINK IN connector and LINK OUT connector are connected...

Page 60: ...sured value value Minimum MIN The minimum measured value value Peak to peak P P The value obtained by subtracting the value minimum value from the maximum value Measuring modes Current value mode maxi...

Page 61: ...e from the master value preset value to the reference point is calculated and the reference point offset value is generated internally and stored After the reference point has been loaded for the seco...

Page 62: ...e this value is set the reference point will be set automatically after the power is next turned on when the spindle of the measuring unit is pushed upward by 1 mm or more To set the reference point a...

Page 63: ...ment output Measured value upper limit Upper limit NG U Measured value upper limit GO G Lower limit measured value upper limit GO G Measured value lower limit GO G Measured value lower limit Lower lim...

Page 64: ...value mode is set as the measuring mode the Go No GO judgment output and the output data are not updated even when the measuring unit is operated When the peak value data update stop function is set t...

Page 65: ...omparator set number 1 Comparator upper limit 0 For all set numbers 1 to 4 Comparator lower limit 0 For all set numbers 1 to 4 Start Hold function Start function RS 232C trigger input setting Low spee...

Page 66: ...h of the units Unit numbers are used in the commands which are input for the settings and operations Do not set the same unit number among linked units Use a screwdriver or other tool to align the dir...

Page 67: ...e parameters are used to set the RS 232C communication specifications Bold print is used to indicate the factory settings Note When using a link connection be sure to use all the same communication se...

Page 68: ...ations Do not use the same number for more than one module in the same unit Setting the same number for more than one module will prevent the system from operating properly 5 3 2 Measuring Unit Settin...

Page 69: ...onds to save data after the CLOSE command has been sent Never turn off the unit s power during this time as the unit may cease to start normally 5 4 1 List of Setup Command Command Setting item SETUP...

Page 70: ...numbers which are equivalent to 0 to 15 under the decimal system is used when the settings are to be established for all units or all modules Setup commands Command Description Write Read SETUP Start...

Page 71: ...ing values be certain after changes have been made that the upper limit value is greater than or equal to the lower limit value Setup commands Command Description Write Read SCN SCN Set the comparator...

Page 72: ...10 s 7 RS 232C trigger not used internal timer 30 s 8 RS 232C trigger not used internal timer 60 s 9 RS 232C trigger not used internal timer 300 s Low speed mode Mechanical contact input relay switch...

Page 73: ...eference point function as well Note All contents other than those set by the setup commands are deleted when the power is turned off Type of operation RS 232C I O connector Measuring mode changes Pre...

Page 74: ...en selectable Stop bit 1 or 2 bits Cable length Max 15 meters Flow control Hardware flow control RTS CTS Use a DZ252 RS 232C cable sold separately Connection 1 2 3 4 5 6 7 8 Case 8pin mini DIN DZ252 1...

Page 75: ...ace zDelimiter 2 bytes CR LF or 1 byte CR Select using communication setting switch No 2 on main unit OFF CR LF factory setting ON CR 6 1 3 Communication Format Communication data output format Channe...

Page 76: ...data is output in the specified communication format see section 6 1 3 beginning from the highest order unit regardless of the unit numbers which have been set The highest order unit is the unit conn...

Page 77: ...all units or all modules 6 1 5 Operation Commands List of operation commands Command Setting item Remarks R Load the data of all the channels r Load the data of specific channels P P Switch to the pea...

Page 78: ...ion No Starting from the leading byte major version minor version Example 0VER 10 Operation commands For the same commands as the setting commands see the list of operation commands refer to section 5...

Page 79: ...I Pause input While the input signal is supplied the updating of the peak value is temporarily stopped 2 I RS trigger input The data of all the channels at the time when the input signal is supplied i...

Page 80: ...onnected device Source type COM Output signal rating On VOL MAX 1 4 V when output current IOL 10 mA Off VOH MAX 26 4 V output current IOH MAX 50 A MG10A P2 input output circuit Input MG10A P2 Photocou...

Page 81: ...eed mode RS trigger input high speed mode Latch input pause input Data Reset input start input MIN 2 ms MAX 2 ms MIN 2 ms The input interval varies with the number of the counter modules used or the R...

Page 82: ...E Example Mode 1 00 Error Mode 2 00NM Error Mode 3 00NME Error The measuring unit was replaced while the power was on Reset The measuring unit is not connected or connection has been cut Remove the c...

Page 83: ...re 10 to 60 C 20 to 90 RH and humidity range 1 The system cannot be configured in such a way that the total power of the modules connected to the MG10A will exceed 54 W when the supply voltage is 12 V...

Page 84: ...K MG30 B1 P2 DT DG B2 8 2 Accessories 7 pin connector for I O made by Phoenix Contact MC1 5 7 ST 3 5 1 pc installed on main unit 3 pin connector for power supply made by Phoenix Contact MC1 5 3 ST 3 5...

Page 85: ...le In the case of link connections are all the MG10A communication settings the same c Problem in the count reading Has the count value overflowed Is the alarm lamp on the MG10A lighted Is the same ma...

Page 86: ...38 E MG10A P1 MG10A P2...

Page 87: ...en Sicherheitsma nahmen vor der Inbetriebnahme Installation Wartung Inspektion oder Reparatur dieses Ger tes oder der Durchf hrung anderer Arbeiten durch Bedeutung der Warnhinweise Bei der Durchsicht...

Page 88: ...nnen auch die internen Stromkreise besch digt werden Dieses Ger t arbeitet mit Gleichstrom Schlie en Sie auf keinen Fall eine Wechselstromquelle an die Klemmen an weil dies zu einem Brand oder elektri...

Page 89: ...unikationsformat 28 6 1 4 Link Verbindung 29 6 1 5 Operationsbefehle 30 6 2 E A Anschluss 32 6 2 1 E A Anschlussstiftbelegung 32 6 2 2 Ein Ausgangsschaltungen 33 6 2 3 Signaltaktgebung 34 1 berblick 1...

Page 90: ...rigen in der Bedienungsanleitung genannten System Produkt und Dienstnamen handelt es sich um Warenzeichen oder eingetragene Warenzeichen ihrer jeweiligen Hersteller 7 Anzeige Ausgabe von Alarm 35 8 Te...

Page 91: ...te Gr e eignet sich ideal f r den Einbau in eine Elektroteiletafel Konstruktion gestattet Installation auf DIN Schienen 35 mm DIN Schienen Erweiterung von 1 bis 16 Kan len durch Modulkonfiguration m g...

Page 92: ...h ltlich MG20A DG F r Serien DG B DL B BR MG20A DT F r Serie DT Schnittstellenmodul BCD Modul MG30 B1 Fotokoppler isolierter Open getrennt erh ltlich Collector Ausgang Stromsenkentyp MG30 B2 Fotokoppl...

Page 93: ...G 3 MG10A P1 MG10A P2 1 3 Systemkonfiguration Computer Messtaster BCD Serie DG Serie DT Serie DL Serie DK PLC Link Max 16 Ger te RS 232C Schlecht Beurteilung Gut...

Page 94: ...4 G MG10A P1 MG10A P2 6 7 4 5 8 2 9 10 11 12 13 14 1 3 2 Teilebezeichnungen und Funktionen...

Page 95: ...es g Stromeingang Hier wird die externe Stromversorgung DC 12 V bis 24 V angeschlossen h RS 232C Anschluss Verbindet das Ger t mit einem Computer oder einem PLC Hostger t Der Steckverbinder am Ende d...

Page 96: ...bereinstimmung mit der Anwendung verwendet werden Bis zu 16 Z hlermodule k nnen angeschlossen werden Entfernen Sie die Gummikappe vom Z hlermodul Steckverbinder an der rechten Seitenwand des Hauptmodu...

Page 97: ...Entfernen der angeschlossenen Z hlermodule F hren Sie die obigen Schritte 1 bis 4 umgekehrt aus Vergessen Sie nicht die Schiebesperren auszurasten bevor Sie die Module entfernen 3 4 3 2 Anschlie en d...

Page 98: ...ittstellenmodul Steckverbinder korrekt ausgerichtet sind 2 Sichern Sie das Schnittstellenmodul mit den Schiebesperren an der Ober und Unterseite Zum Entfernen des angeschlossenen Schnittstellenmoduls...

Page 99: ...ie Oberkante der DIN Schiene aus 1 Installieren Sie das Ger t indem Sie es auf die Schiene dr cken bis ein Klicken zu h ren ist so dass die Unterseite der Nut an der R ckwand des Ger tes fest auf der...

Page 100: ...schluss des falschen Messtasters kann ein Ausfall des Anschlusses verursacht werden 1 3 5 Anschlie en der Stromversorgung Verdrahten Sie den mitgelieferten 3 poligen Stecker mit der externen Stromquel...

Page 101: ...abel nicht lang genug ist verl ngern Sie es mit dem getrennt erh ltlichen Verl ngerungskabel CE08 Das Multi Schnittstellenger t funktioniert nicht wenn die Buchsen LINK IN und LINK OUT verkehrt herum...

Page 102: ...egenw rtig gemessene Wert Maximalwert MAX Der gemessene Maximalwert Minimalwert MIN Der gemessene Minimalwert Spitze Spitze Wert Der durch Subtrahieren des Minimalwertes vom Maximalwert erhaltene Wert...

Page 103: ...d die Entfernung vom Hauptwert Voreinstellungswert bis zum Bezugspunkt berechnet und der Bezugspunkt Versatzwert wird intern erzeugt und gespeichert Nach dem zweiten und jedem weiteren Laden des Bezug...

Page 104: ...wird der Bezugspunkt automatisch eingestellt nachdem die Stromversorgung das n chste Mal eingeschaltet oder die Spindel des Messtasters um 1 mm oder mehr hochgedr ckt worden ist Um den Bezugspunkt ern...

Page 105: ...swert Beurteilung RS 232C Beurteilungsausgabe Messwert Obergrenze Obergrenze NG U Messwert Obergrenze Gut G Untergrenze Messwert Obergrenze Gut G Messwert Untergrenze Gut G Messwert Untergrenze Unterg...

Page 106: ...dus eingestellt ist erfolgt keine Aktualisierung der Gut Schlecht Beurteilungsausgabe und der Ausgabedaten selbst wenn der Messtaster bet tigt wird Wenn die Spitzenwert Datenaktualisierungs Stoppfunkt...

Page 107: ...Satznummern von 1 bis 4 Komparator Untergrenze 0 F r alle Satznummern von 1 bis 4 Start Halte Einstellung Startfunktion RS 232C Ausl sereingabe Niedergeschwindigkeitsmodus Einstellung Einstellung Einh...

Page 108: ...chte Nummer auszurichten Einstellbereich 0 bis F 1 5 2 2 Kommunikationsparameter Einstellungen Diese Parameter werden zur Einstellung der RS 232C Kommunikationsspezifikationen verwendet Die Werkseinst...

Page 109: ...OFF 19200 bps OFF ON 38400 bps ON ON Datenl ngen Einstellung SW 6 8 bit OFF 7 bit ON Stoppbit Einstellung SW 5 1 bit OFF 2 bit ON Parit tseinstellung SW 3 SW 4 OFF OFF OFF ON Even ON OFF ON Odd ON ON...

Page 110: ...den Verwenden Sie nicht dieselbe Nummber f r mehr als ein Modul in einer Einheit Wird dieselbe Nummer f r mehr als ein Modul eingestellt arbeitet das System nicht einwandfrei 5 3 2 Messtaster Einstell...

Page 111: ...Daten maximal 3 Sekunden W hrend dieser Zeitdauer darf die Stromversorgung des Ger tes auf keinen Fall ausgeschaltet werden da es anderenfalls u U nicht mehr normal arbeitet 5 4 1 Liste der Einrichtun...

Page 112: ...s F sind Hexadezimalzahlen die im Dezimalsystem 0 bis 15 entsprechen wird verwendet wenn die Einstellungen f r alle Ger te oder Module gelten sollen Einrichtungsbefehle Befehl Beschreibung Schreiben L...

Page 113: ...e tats chliche Obergrenze kleiner ist als die Untergrenze Vergewissern Sie nach einer nderung der Einstellwerte unbedingt dass der Wert der Obergrenze gleich oder gr er als der Wert der Untergrenze is...

Page 114: ...mer 0 5 s 4 RS 232C Ausl ser nicht benutzt interner Timer 1 0 s 5 RS 232C Ausl ser nicht benutzt interner Timer 5 0 s 6 RS 232C Ausl ser nicht benutzt interner Timer 10 s 7 RS 232C Ausl ser nicht benu...

Page 115: ...n Lesen SCALE Zur Einstellung der Ma einheit mm Zoll Befehlsformat aSCALE c c 0 mm 1 1 25 4 mm CLOSE Zum Beenden der Parameter Einrichtung Befehlsformat CLOSE Zum Beenden der Parameter Einrichtung und...

Page 116: ...2 3 Bezugspunkt Bezug nehmen Beim Ausschalten der Stromversorgung werden alle Inhalte au er den mit den Einrichtungsbefehlen eingestellten Parameter gel scht Operationstyp RS 232C E A Anschluss Messmo...

Page 117: ...er gerade w hlbar Stoppbit 1 oder 2 Bit Kabell nge Max 15 m Ablaufsteuerung Hardware Ablaufsteuerung RTS CTS Verwenden Sie ein RS 232C Kabel DZ252 getrennt erh ltlich Anschlu 1 2 3 4 5 6 7 8 Kasten 8p...

Page 118: ...erkseinstellung Leerstelle zBegrenzer 2 Byte CR LF oder 1 Byte CR Wahl mittels Kommunikations Einstellschalter Nr 2 am Hauptger t OFF CR LF Werkseinstellung ON CR 6 1 3 Kommunikationsformat Kommunikat...

Page 119: ...chstrangigen Ger t ungeachtet der eingestellten Ger tenummern ausgegeben Das h chstrangige Ger t ist das an das Hostger t PC oder PLC angeschlossene Ger t und die untergeordneten Ger te werden entspre...

Page 120: ...Einzelheiten zum Einstellen Komparator Satznummer dieser Nummer in Abschnitt 5 4 PAU Zum Aktivieren des Spitzenwert Datenaktualisierungsstopps LCH Zum Aktivieren der Istwert Ausgabedatenspeicherung L...

Page 121: ...der Befehlseingabe erzeugten Istwert als Maximal und Minimalwert ein Null f r Spitze Spitze Wert und starten Sie die Spitzenwertmessung Befehl Beschreibung PAU Zum Aktivieren des Spitzenwert Befehlsf...

Page 122: ...gew hlt wird Die Spitzenwertaktualisierung beginnt sobald das Eingangssignal zugef hrt wird Wenn die Speicherfunktion gew hlt wird W hrend das Eingangssignal zugef hrt wird wird der Wert mit dem Istw...

Page 123: ...ngeschlossenes Ger t Quellentyp COM Ausgangssignal Kenndaten Ein VOL MAX 1 4 V Ausgangsstrom IOL 10 mA Aus VOH MAX 26 4 V Ausgangsstrom IOH MAX 50 A MG10A P2 Ein Ausgangsschaltung MG10A P2 COM COM COM...

Page 124: ...ngabe Hochgeschwindigkeitsmodus Speichereingabe Pauseneingabe Daten R ckstellungseingabe Starteingabe MIN 2 ms MAX 2 ms MIN 2 ms Der Eingabeabstand ist je nach der Anzahl der verwendeten Z hlermodulen...

Page 125: ...es 3 00NME Error Der Messtaster wurde bei eingeschalteter Stromversorgung ausgewechselt R ckstellung Der Messtaster ist nicht angeschlossen oder die Verbindung ist unterbrochen worden Die Fehlerursach...

Page 126: ...ertemperatur 10 bis 60 C 20 bis 90 RH und luftfeuchtigkeitsbereich 1 Das System kann nicht so konfiguriert werden dass die Gesamtleistung der an das MG10A angeschlossenen Module 54 W oder 108 W bersch...

Page 127: ...G B2 P2 8 2 Zubeh r 7 poliger Steckverbinder f r E A von Phoenix Contact MC1 5 7 ST 3 5 1 St ck am Hauptger t installiert 3 poliger Steckverbinder f r Stromversorgung von Phoenix Contact MC1 5 3 ST 3...

Page 128: ...he des Kommunikationskabels Sind im Falle von Link Verbindungen alle Kommunikationseinstellungen am MG10A gleich c Falscher Z hlerwert Ist ein Z hlerwert berlauf aufgetreten Leuchtet die Alarmlampe a...

Page 129: ......

Page 130: ...ent l usage des acqu reurs de l quipement d crit dans ce manuel Magnescale Co Ltd interdit formellement la copie de quelque partie que ce soit de ce manuel ou son emploi pour tout autre but que des op...

Page 131: ...MG10A P1 MG10A P2 1...

Page 132: ...45 Suzukawa Isehara shi Kanagawa 259 1146 Japan 1 16 16 For foreign customers Note This product or technology may be restricted by the government in your country Please make sure that end use end user...

Reviews: