EN
29
www.magmaweld.com
USER MANUAL | MANUEL D’UTILISATION | РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ | KULLANIM KILAVUZU
ID 500 TW DC PULSE
4.3 Error Codes
The following tables contain possible errors to be encountered and their solutions.
E01
Thermal
Protection
(Primary)
Check the mains connection cables
and voltage. Make sure that the
correct voltage input is provided. If
the mains voltage is normal, contact
the authorized service
Mains voltage may have decreased
Check the mains connection cables
and voltage. Make sure that the
correct voltage input is provided. If
the mains voltage is normal, contact
the authorized service
Mains voltage may have increased
Contact the authorized service
Temperature sensor may have failed
or there may be an electrical
connection problem
Contact the authorized service
There may be electrical problems in
the machine
The machine’s run time duty cycle
rate may have been exceeded
Wait for a while to allow the machine
to cool down. If the failure
disappears, try to run the machine at
lower amperage values
The machine operating environment
can be extremely hot or lack of air
Ensure that the machine is placed in
an area where it can work operate
comfortably
The air inlet and outlet ducts may
have been blocked
Open the air ducts
Fan may not be operating
Visually inspect the fan for proper
operation. Please contact the
authorized service if it does not
operate
E02
Low Mains
Voltage
E03
High Mains
Voltage
E05
E07
Temperature
Sensor Failure
High Output
Voltage
Error Code
Error
Reason
Solution
Contact the authorized service
Low mains voltage may be present
E09
High Primary
Current
Contact the authorized service
There may be electrical problems in
the machine
Contact the authorized service
There may be electrical problems in
the machine
Wait for a while to allow the machine
to cool down. If the failure
disappears, try to run the machine at
lower cycle rates
The machine’s run time duty cycle
rate may have been exceeded
E12
E14
E19
VRD Error
Communication
Error
Thermal
Protection
(Secondary)
Maintenance and Service
Summary of Contents for D 500 TW DC PULSE
Page 1: ...ID 500 TW DC PULSE 90 444 93 53 magmaweld com info magmaweld com 90 538 927 12 62 USER MANUAL...
Page 64: ...RU 64 www magmaweld com USER MANUAL MANUEL D UTILISATION KULLANIM KILAVUZU ID 500 TW DC PULSE...
Page 67: ...RU 67 www magmaweld com USER MANUAL MANUEL D UTILISATION KULLANIM KILAVUZU ID 500 TW DC PULSE...
Page 71: ...RU 71 www magmaweld com USER MANUAL MANUEL D UTILISATION KULLANIM KILAVUZU ID 500 TW DC PULSE...
Page 126: ......
Page 127: ......
Page 129: ......
Page 130: ......
Page 131: ......