EN
25
www.magmaweld.com
USER MANUAL | MANUEL D’UTILISATION | РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ | KULLANIM KILAVUZU
ID 500 TW DC PULSE
3.2 TIG Curve
The function statuses in on or off positions according to the modes are as follows.
** Spot Welding Time
Pre-Gas
Initial
Current
Start Ramp
Lower
Current
End Ramp
Final
Current
Final Gas
Pulse
Frequency
Higher Curren
t
Pulse
(Width)
Pre-Gas Period
Final Gas Period
0-20 sec
1 sec
5 sec
Start Ramp Time
Water Cooling Time
Lower Current
Pulse Frequency
Final Current
0.0-10 sec
-
5A-%100
0.1-2000 Hz
5A-%100
1 sec
3 min
40 A
5 Hz
%30
Initial Current
Spot Time
Upper Current
Pulse Cycle Rate
End Ramp Time
5A-%100
0-20 sec
0-20 sec
5-500 A
%1-%99
0.0-10 sec
%70
2 sec
85 A
%50
1 sec
Parameter
ID 500 TW DC PULSE
Factory Setting 2 Position TIG
DC
PULSE
4 Position TIG
DC
PULSE
Pnt TIG
DC
PULSE
Operation
Summary of Contents for D 500 TW DC PULSE
Page 1: ...ID 500 TW DC PULSE 90 444 93 53 magmaweld com info magmaweld com 90 538 927 12 62 USER MANUAL...
Page 64: ...RU 64 www magmaweld com USER MANUAL MANUEL D UTILISATION KULLANIM KILAVUZU ID 500 TW DC PULSE...
Page 67: ...RU 67 www magmaweld com USER MANUAL MANUEL D UTILISATION KULLANIM KILAVUZU ID 500 TW DC PULSE...
Page 71: ...RU 71 www magmaweld com USER MANUAL MANUEL D UTILISATION KULLANIM KILAVUZU ID 500 TW DC PULSE...
Page 126: ......
Page 127: ......
Page 129: ......
Page 130: ......
Page 131: ......