Page 41
4. S
ERVICING
I
NSTRUCTIONS
4.1. General
Requirements
All repairs and servicing must be carried out by a qualified registered gas installer (e.g.
member of Gas Safe in GB) in accordance with the current Gas Safety (Installation and Use)
Regulations and these instructions.
Before any servicing is carried out ensure that the gas and electrical supply (where applicable)
have been isolated.
After any servicing or replacement of any parts, the appliance should be re-commissioned.
4.2. Servicing
Instructions
As part of the appliance service, the flue and
fireplace opening should be checked for
soundness and any debris removed. For this
the fascia and the firebox will need removal.
Refer to sections
3.9.6
or
3.9.7
for removing
the fascia.
Refer to the section:
2.7.1 – Cleaning the Fire-bed
on
Page 18
and section:
2.7.2
-
Cleaning the Pilot
on
Page 19
.
On completion of the servicing, a spillage
test must be carried out.
WARNING: ODS Pilot Assembly
Under no circumstances should the pilot assembly be adjusted or put out of
action by the installer. In case the pilot needs replacing, only the approved part
(available from your supplier or Magiglo Ltd.) should be fitted. Note: if any part of
the pilot assembly becomes faulty the complete assembly will need replacing.