214658
102
Revision A
Calibrating Auto Header Height Control (John Deere 70 Series)
NOTE:
Changes may have been made to combine controls or display since this document was published. Refer to
combine operator
’
s manual for updates.
CAUTION
Check to be sure all bystanders have cleared the area.
1.
Start combine.
1003597
A
B
Figure 6.57: John Deere Combine Display
2.
Press button located fourth from left along top of
monitor (A) to select icon that resembles an open book
with a wrench on it (B).
3.
Press button (A) a second time to enter diagnostics and
calibration mode.
1015017
A
B
Figure 6.58: John Deere Combine Display
4.
Select HEADER in box (A) by scrolling down to box
using the scroll knob, and then by pressing the check
mark button.
NOTE:
The knob and button are shown in figures at right.
5.
Scroll down to the lower right icon that resembles an
arrow in a diamond (B) and press the check mark
button to select it.
6.
Follow the steps listed on the combine display to
perform the calibration.
NOTE:
If an error code appears on page, then the sensor is not in
the correct working range. Refer to
from Combine Cab (John Deere 70 Series), page 101
to
check and adjust range.