![MA lighting dimMA Manual Download Page 85](http://html1.mh-extra.com/html/ma-lighting/dimma/dimma_manual_3144365085.webp)
MA Lighting Technology GmbH . Dachdeckerstr. 16 . D-97297 Waldbüttelbrunn . www.malighting.com eMail: [email protected]
22
VIEW menu
Here, you can find the brightness values of the outputs displayed in %. You will only see existing elements, i.e.
you can set the menu number blocks only to those numbers present. You cannot make any changes in this
menu.
VIEW DIMMER:
●
Enter the Rack, Crate, module, and dimmer numbers and confirm with ENTER or OK.
On the right side, you will find the brightness value of the chosen dimmer in %.
VIEW CRATE:
●
Enter Rack and Crate number and confirm with ENTER or OK.
Note: The items appearing on the display of the NDP will, due to technical reasons, differ from what you see on an
external monitor. The NDP displays the outputs as bars, whereas the monitor will us numbers.
In the graphics on the left side, you see the outputs of Crate 1 of Rack 1. Each first dimmer of every module
displays the starting values.
VIEW DMX:
●
Select a DMX input (1 or 2)
●
Set the DMX channel
The setting will be displayed as % value
●
Confirm using the OK key or press ENTER and exit the menu using the ESC key or the arrow key on the left
side