![MA lighting dimMA Manual Download Page 71](http://html1.mh-extra.com/html/ma-lighting/dimma/dimma_manual_3144365071.webp)
MA Lighting Technology GmbH . Dachdeckerstr. 16 . D-97297 Waldbüttelbrunn . www.malighting.com eMail: [email protected]
8
TEMP
flash: Warning (there is an over temperature in the unit- over75°C (167°F))
continuous: Output load is disconnected due to over temperature ( - over 90°C ( 194°F))
Fan switch at 40°C (104 °F) at level 1, at 50°C (122°F) at level 2.
LOAD
lights when the threshold is reached according to the connected load:
(All values refer to the use of halogen bulbs)
CTR (Control)
wi
ll be on, if a control signal is being received (normal operating status)
L1 / L2 / L3
will be on, if there is a power supply to the module (normal operating status)
Setting (only necessary for the first start-up)
Addressing:
Adjust the address of each Compact dimmer unit by turning the blue rotary switch. Each Compact Dimmer-unit
needs a unique number - avoid same number at two or more units!
For the at most 12 Compact dimmer units the numbers 1-9 and the letters A,B or C are intended. Other
adjusments or double adjustment can cause malfunction of the
dimmer.
Controls and connection (COMPACT)
NOTE: In case of failure of two phases dimMA no longer works correctly. The loss of one phase is straightforward.
dimMA compact module 12 x 3kVA
dimMA compact module 6 x 5,7kVA
with a connected load of:
threshold in%
with a connected load of:
threshold in %
3kW
0,5%
5kW
1%
2kW
2%
4kW
2%
1kW
5%
3kW
5%
2kW
5%
1kW
7%
Minimum rated load for the load function: 200W
Minimum rated load for the load function: 300W