![M-system TC10EM Instruction Manual Download Page 34](http://html1.mh-extra.com/html/m-system/tc10em/tc10em_instruction-manual_3132373034.webp)
TC10EM
P. 34 / 43
EM-9581-B Rev.1
5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN
Phone: +81(6)6659-8201 Fax: +81(6)6659-8510 E-mail: [email protected]
DISPLAY SETTING
Display setting of the unit can be configured.
■
BRIGHTNESS
The brightness of the display can be adjusted with 0 to 3, 4 levels. “3” is brightest.
ADDRESS
PARAMETER
RANGE
DEFAULT
769
Brightness
0 – 3
3
MODBUS COMMUNICATION CONFIGURATION
Modbus communication configuration can be set. Be sure that the communication condition set here is updated immediately.
■
NODE ADDRESS
ADDRESS
PARAMETER
RANGE
DEFAULT
2049
Node address
1 – 247
1
■
BAUD RATE
ADDRESS
PARAMETER
RANGE
DEFAULT
2050
Baud rate
0: 57600 bps
1: 38400 bps
2: 19200 bps
3: 9600 bps
4: 4800 bps
1
■
PARITY
ADDRESS
PARAMETER
RANGE
DEFAULT
2051
Parity
0: None
1: Odd
2: Even
1
■
STOP BIT
ADDRESS
PARAMETER
RANGE
DEFAULT
2052
Stop bit
0: 1 bit
1: 2 bits
0