47DV
P. 26 / 34
EM-9501-B Rev.6
PARAMETER
Backlight brightness
*
5
Contrast level 1 (low)
Brightness level 2
Brightness level 3 (bright)
Brightness level 1 (dark)
FUNCTION
DEFAULT
VALUE
MAIN DISPLAY
SUB DISPLAY
Disabled
Enabled via the front button control
LCD Contrast
*
5
Bank switching
*
5
Contrast level 2
Firmware version indication
Version number, indication only
N/A
N/A
Enabled via Modbus communication
Contrast level 3
Contrast level 4
Contrast level 5
Contrast level 6
Contrast level 7
Contrast level 8
Contrast level 9
Contrast level 10 (high)
Request valid at ON
Request valid at OFF
REQ input logic
*
5
Data valid at ON
Data valid at OFF
DAV output logic
*
5
Negative logic open collector
Positive logic open collector
DATA output logic
*
5
Valid at ON
Valid at OFF
Status output logic
*
5,
*
11
*
5. Selectable only at Advanced Setting Lockout Level LV0.
*
6. Latched output is reset when the latching is set to OFF while the output is latched.
*
8. Standby sequence setting is invalid when the alarm ON delay is set (except for P zone).
Do not try to control the panel meter while it is in the standby sequence.
*
9. With no alarm output type, all alarm indicators turn off at an over-range error.
*
10. The changes on the settings are effective after power OFF and restart.
*
11. Output logic for RUN, LL, L, P, H, HH, POL and OVF.
Round off low-digit reading
*
5
1
10
5
2
Display reading type
*
5
Measured value
Minimum value
Maximum value
Standby sequence
*
6,
*
8,
*
10
No alarm trip action at over-range
Output immediately at the startup
Output standing by until the input enters P zone
Scaling error
*
5,
*
9
Alarm trip action valid at over-range
High-pass filter ON
High-pass filter OFF
High-pass filter
*
5