![background image](http://html1.mh-extra.com/html/lutron-electronics/aurora-ar-ent-2s3d-series/aurora-ar-ent-2s3d-series_package-installation-manual_1951053025.webp)
Lutron
|
25
Need help? Contact Lutron Technical Support 24/7: 800.523.9466
troubleshooting
Symptom
Possible Cause
Remedy
Dimmer/switch keeps
turning on and off.
Unit has been wired
incorrectly.
Wattage is under
recommended minimum load.
2 or more AuroRa
®
dimmers/
switches on one circuit.
Refer to wiring instructions.
See number 2 under either
Dimmers or Switches on
page 21.
Remove and replace
additional
AuroRa
dimmer
with standard single pole
or 3-way switch.
Dimmer/switch performs
nor mal ly when op er at ed
manually, but fails to respond
to master control button
pushes.
The dimmer/switch may be
out of communication range
of the central antenna.
The master control may be
out of communication range
of the central antenna.
Move the central antenna
closer to the dimmer/switch.
Move central antenna closer
to master control.