1
2
3
✓
Lutron
|
12
Need help? Contact Lutron Technical Support 24/7: 800.523.9466
lights controlled by three or more switches
Remove wallplate
OR
Designer
Traditional
Turn power off at circuit
breaker or remove fuse
Locate a switch with three insulated wires attached to it
✓
Helpful Hint:
Save your wallplate and screws.
1
2
4
3
1
2
3
NOTE:
Do not disconnect the switch
if it has four wires attached to
it, remount it and remove one
of the other two switches. The
AuroRa
dimmer/switch
cannot
be used in a switch location that
has four wires.
NOTE:
You only need to replace one of the switches controlling
the light with an AuroRa
®
dimmer/switch.
Unscrew existing switch and
pull it forward out of the wall
(do not disconnect wires yet)
B.
Three insulated wires inserted
into back of existing switch.
One ground wire attached to
a screw.
To uninstall switch, refer to
step 4 Figure 4B.
A.
Three insulated wires each
attached to a screw. One
ground wire (green or bare)
attached to a screw.
To uninstall switch, refer to
step 4 Figure 4A.
Once switch is pulled out, you should see one of the following:
incorrect (4 wires)
correct (3 wires)
✓
Helpful Hint:
For wiring diagram for lights
controlled by three or more
switches see step 3C on page 21.
To avoid fire, shock or
death,
turn power off
at corresponding circuit
breaker or remove fuse.
WARNING