33
20.
Troubleshooting
WARNING!
Any faults on the machine or engine requiring major intervention must always be repaired by your LUMAG
workshop or authorised specialist workshops. The warranty becomes void in the event of improper
intervention.
Before any troubleshooting
–
Switch off machine
–
Wait for the shredding blades to come to a standstill
–
Remove spark plug connector.
PROBLEM
POSSIBLE CAUSE
PROPOSED REMEDY
Engine will not start
No fuel
Fill fuel tank
Recoil starter defective
Repair or replace recoil starter
Do not
refill engine oil
Engine is still in the cooling phase
Let engine cool down
No spark
Clean or replace spark plug
Engine in cold condition and choke set to
OPEN (right)
Set choke to CLOSE position (left)
Fuel switch set to OFF
Set fuel switch to ON
Engine is difficult to start or runs
poorly
Fuel mixture too greasy
Set choke to OPEN (right) position
Carburettor incorrectly adjusted
Have adjustment carried out by specialist
dealer
Faulty spark plug, dirty or incorrectly
adjusted
Clean, readjust or replace spark plug
Engine gets too hot
Too little engine oil
Refill engine oil
Cooling air system restricted
Clean ventilation grille, clean internal
cooling fins
Air filter dirty
Clean filter element, replace if necessary
Carburettor not adjusted correctly
Have carburettor adjusted by specialist
dealer
Engine brings too little power
Air filter dirty
Clean filter element, replace if necessary
Machine is overloaded
Reduce material supply, observe max. Ø of
branches!
Machine is blocked
Clean the machine thoroughly from the
inside
Reduced cutting performance
and / or decreases
Blades are dull
Turn or replace the blade
Counter blade is worn
Turn or replace counter blade
V-belt slips
Tension the V-belt
Shredded material is not
automatically drawn in
Blades are dull
Turn or replace the blade
Excessive vibration
Blades, screws, nuts or other parts loose
Switch off engine immediately. Check all
nuts and screws for tight fit, replace
damaged parts, adjust V-belt tension.
If these measures do not eliminate the fault or if faults occur which are not listed here, then have your machine
checked by a specialist.