![LS Industrial Systems SV-iS7 PLC User Manual Download Page 135](http://html.mh-extra.com/html/ls-industrial-systems/sv-is7-plc/sv-is7-plc_user-manual_1943813135.webp)
Appendix 4 Common Area Parameter of iS7 Inverter
Appendix 4
-3
Address
Parameter
Scale
Unit
R/W
Detailed Description
BIT7
None
BIT6
None
BIT5
Q4 (Expansion IO Relay Output 3)
BIT4
Q3 (Expansion IO Relay Output 2)
BIT3
Q2 (Expansion IO Relay Output 1)
BIT2
Q1 (Basic IO TR Output1)
BIT1
Relay2 (Basic IO Relay Output 2)
BIT0
Relay1 (Basic IO Relay Output1)
BIT15
0: OFF State 1: ON State
(COM85:Virtual DI16)
BIT14
0: OFF State 1: ON State
(COM84:Virtual DI15)
BIT13
0: OFF State 1: ON State
(COM83:Virtual DI14)
BIT12
0: OFF State 1: ON State
(COM82:Virtual DI13)
BIT11
0: OFF State 1: ON State
(COM81:Virtual DI12)
BIT10
0: OFF State 1: ON State
(COM80:Virtual DI11)
BIT9
0: OFF State 1: ON State
(COM79:Virtual DI10)
BIT8
0: OFF State 1: ON State
(COM78:Virtual DI9)
BIT7
0: OFF State 1: ON State
(COM77:Virtual DI8)
BIT6
0: OFF State 1: ON State
(COM76:Virtual DI7)
BIT5
0: OFF State 1: ON State
(COM75:Virtual DI6)
BIT4
0: OFF State 1: ON State
(COM74:Virtual DI5)
BIT3
0: OFF State 1: ON State
(COM73:Virtual DI4)
BIT2
0: OFF State 1: ON State
(COM72:Virtual DI3)
BIT1
0: OFF State 1: ON State
(COM71:Virtual DI2)
0x0322
Virtual Digital Input
Information
- -
R
BIT0
0: OFF State 1: ON State
(COM70:Virtual DI1)
0x0323 Show
selected
Motor
-
-
R
0: First motor, 1:Second motor
0x0324
AI1
0.01
%
R
analog input1 (basic I/O)
0x0325
AI2
0.01
%
R
analog input2 (basic I/O)
0x0326
AI3
0.01
%
R
analog input3 (extended I/O)
0x0327
AI4
0.01
%
R
analog input4 (extended I/O)
0x0328
AO1
0.01
%
R
analog output1 (basic I/O)
0x0329
AO2
0.01
%
R
analog output2 (basic I/O)
0x032A
AO3
0.01
%
R
analog output3 (extended I/O)
0x032B
AO4
0.01
%
R
analog output4 (extended I/O)
0x032C Reserved
- - -
-
0x032D Reserved
- - -
-
0x032E Reserved
- - -
-
0x032F Reserved
- - -
-
BIT1
5
Fuse Open Trip
0x0330
latch type trip
information-1
- -
R
BIT1
Overheat Trip