63
THIS MANUAL IS PROPRIETY OF
ECOWIND by LOMBARDINI
- ALL FORMS OF REPRODUCTION, PARTIAL OR OTHERWISE, IS STRICTLY PROHIBITED
G
B
Fig. 145
PL + PH
AC
TS
3 -
ASSEMBLY AND INSTALLATION
ATTENTION
As the system is pressurised, specific operations
on the thermodynamic plant must be carried out in
full compliance with the regulations for systems
containing HFCs and must only be performed by
an
authorised service centre. Lombar-
dini S.r.l declines all responsibility for accidents
and/or damage deriving from non-observance of
this regulation.
Safety warnings
Frequency of system refilling.
It is recommended to refill the system with R 134 a
(TETRAFLUORETHANE) at least once a season, in order to
ensure an optimum system performance.
NB:
It is extremely important to observe the quantities given on
page 10÷11
ATTENTION
PRESSURIZED SYSTEM
Before performing any maintenance operations on the gas circuit, it is absolutely essential
to empty the pressurised system (R 134 a) using the specific charger/recovery station not
supplied.
Pay the utmost attention, when disconnecting the TS service pipes as they may contain
pressurized coolant!!
Avoid direct skin and eye contact with coolant!!
NB: Wear protective goggles and gloves.
The coolant has a boiling temperature (in normal environmental conditions) of about
-26 °C (~ -14.8 °F).
Non-observance of this regulation could cause burns and serious harm to the
operator!!!
It is strictly forbidden to release and/or dispose of the coolant GAS (R 134a) and the
compressor lubricating oil contained in the refrigerating circuit into the environment.
ECOWIND by Lombardini declines all responsibility for damage caused to things, persons,
animals or the equipment itself as a result of non-observance of this regulation
.