![Lombardini ECOWIND 350 C - EUR 12V Assembly And Installation Manual Download Page 133](http://html.mh-extra.com/html/lombardini/ecowind-350-c-eur-12v/ecowind-350-c-eur-12v_assembly-and-installation-manual_1938340133.webp)
59
THIS MANUAL IS PROPRIETY OF
ECOWIND by LOMBARDINI
- ALL FORMS OF REPRODUCTION, PARTIAL OR OTHERWISE, IS STRICTLY PROHIBITED
G
B
F1
M
Fig. 121
W
Fig. 122
OR
Fig. 120
F1
F2
Fig. 119
V
B
3 -
ASSEMBLY AND INSTALLATION
Step Description
4
Closed the circuit of refrigerant, bended the metallic fitting
F1
with insulating mastic supplied
M
as showed in fig. ,
against eventually problem of condensation. At the end of all operation repose in original position the adhesive gasket
W
as showed in fig.
Step Description
3
Insert in the valve
K
the fitting
F1
and
F2
as showed in fig. 119 and close it, with screw
V
and bracket
B
previous
conserved.
Before to tighten fittings, always verify that there are the O-ring OR inserted see fig. 120. Remember always to lubricate
and close all the fittings as recommended on tab 9 pag. 39