50 rpm 0 rpm
RPM TERMINAL
MANUAL
P = 0W 0 rpm
♥
= 0/m
esc P
0Watt
F
0 Watt Start-up System 925805
With option 925805 your ergometer is able to start the ergometer without load (0 watt) at a
preset pedal speed (rpm). You can choose any pedal speed between 30 and 80 rpm. The
number of revolutions is increased from 0 to the required rpm by means of a motor drive.
With this option there is no energy-loss due to the start-up phase. This option has to be built-
in in the ergometer while manufacturing and cannot be added later on.
F.1
Using the 0 Watt start-up system
When you are in the MANUAL, TERMINAL or ANALOG mode you can go to the 0 watt by
pressing the
( )
(enter) button. The following menu appears (Terminal):
In the upper left the target rpm is shown. The default value is 50. The current rpm is shown on
the upper right. The maximum target rpm is 80 the minimum value is 30 rpm. With the up and
down key's the target rpm can be changed to the desired value. When entering the menu the
system is not started but begins on the first button press of the up or down key. When the
current rpm is over the target rpm the system is released. And the system stops. The menu
also returns to the previous selection (Terminal).
The test subject can now start pedaling.
F.2
0 Watt Start-up system with P-display
In case the 0-Watt option is available it is followed for approximately 1 second by thereby
indicating the device is detected.
When using the 0 Watt option from the P-display it can also be used from TERMINAL,
MANUAL or ANALOG mode. When selected the following is shown (manual case).