Measurement • 82
Gocator 2000 Family
Center X
A Center X measurement finds the average location of two features points and measures the x-axis
position of the average location. The measurement value can be compared with minimum and maximum
constraints to yield a decision.
To create or edit a Center X measurement:
1
Add a new Center X measurement or select an existing Center X measurement.
2
Adjust the feature point areas.
A Center X measurement requires two feature points.
3
Specify the types of feature points to be detected.
Refer to the Feature Points section (page 70) in this chapter for information on point types.
4
Provide minimum and maximum constraints for a decision.
Refer to the Decisions section (page 74) in this chapter for more information on decisions.
Summary of Contents for Gocator 2000 Family
Page 1: ...User s Manual Gocator 2000 Family Version 2 2 1 0 Revision A...
Page 164: ...Specifications 164 Gocator 2000 Family Envelope 61 25 40 5 4 15 82 9 95 7...
Page 166: ...Specifications 166 Gocator 2000 Family Envelope 33 90 80 2 9 84 3 99 7 10 6...
Page 168: ...Specifications 168 Gocator 2000 Family Envelope 190 210 33 141 3 155 7 4 11...
Page 170: ...Specifications 170 Gocator 2000 Family Envelope 33 300 400 214 9 229 2 10 3 3 2...
Page 172: ...Specifications 172 Gocator 2000 Family Envelope 33 400 500 216 2 230 6 3 9 11...