Instructions
Saddle-mount unit GSG-S-VM
32 - 72
010710-03-EN BA GSG-S-VM / 13.07.2020
Select nozzles based on the calculated driving speed and the
desired distribution quantity so that the required nozzle dis-
charge is distributed in the pressure range between 7 and 12
bar.
Check the liquid discharge (l/min) now at the unit.
Measurement:
Conduct the measurement using water only.
•
Fill the tank with water to a clearly visible mark. The marking
should preferably be in the narrowest point in the filling mandrel,
since the small diameter there immediately shows small changes
in the liquid level.
This provides for a more accurate measurement and reduces the
time required for measuring.
•
After filling the tank with water, set the required pressure using
the buttons on the control box with the spray nozzles switched
on.
The pressure to be set is based on the calculated engine RPM
for the optimum driving speed.
•
Fill all lines in the system with liquid. Air in the system will result
in an incorrect measurement.