Operating Manual
Cross-flow fan unit type GSG-NV1 / 2
24 - 64
010980-26-E BA GSG-NV1_2 / 23.03.2012
Universal joint shaft guard:
Secured safety chains prevent
the two-sided universal joint
shaft guard from turning during
operation.
Guard
Fig. 17
Picture shows universal joint shaft on lateral support (e.g. during
storage in wintertime)
During spraying the universal joint shaft must be able to turn
freely and must not come into contact with the universal joints
shaft storage bracket.
Connect safety chains for the universal joint shaft guard so that a
sufficient swiveling area for the universal joint shaft is ensured in
all operating positions. Do not use safety chains for suspending
the universal joint shaft!
Universal joint shaft guard:
Picture shows lateral support in
retracted position during spray-
ing operation.
Fig. 18