Enclosure
NTI AG / LinMot
®
www.LinMot.com 29 / 32
Storage, Transport, Installation Altitude
Lagerung, Transport, Aufstellhöhe
•
Sliders are to be stored and transported only in the plastic containers (with cardboard inlay)
provided for this purpose, or already installed and secured in LinMot P stators.
•
Remove the slider from these plastic containers only for assembling.
•
The storage area must be dry, dust-free, frost-free and vibration-free.
•
Prescribed storage temperature: -
15 °C…70 °C
•
The motor must be protected against extreme weather conditions.
•
The air in the storage area must not contain any harmful gases.
•
The max. installation altitude is 4'000 m above sea level.
From 1'000 m, derating of 1 °C per 100 m is to be considered for air cooling.
•
LinMot Läufer dürfen ausschliesslich in der Orginalverpackung transportiert und gelagert
werden.
•
Die Läufer sollten erst beim Einbau aus der Verpackung genommen werden.
•
Der Lagerraum muss trocken, staubfrei, frostfrei und erschütterungsfrei sein.
•
Vorgeschriebene Lagertemperatur: -
15 °C…70 °C
•
Der Motor muss vor extremen Witterungen geschützt werden.
•
Die Raumluft darf keine aggressiven Gase enthalten.
•
Die maximale Aufstellhöhe beträgt 4'000 m ü. M.
Ab 1'000 m ist bei Luftkühlung ein Derating von 1 °C pro 100 m zu berücksichtigen.