-70-
SEND Command (Data Transmission Command)
The SEND command is used to transmit data from your analyzer.
1 ) SEND CHR □□□□□□□□ (Character Line Transmission Command)
<Entering>
Cursor Position
Enter & Operation
Command Field 1
Sub-Command Field 0
Operand Field
Enter a string of up to 8 characters in hexadecimal code. To enter a string of less than 8
characters,finish the entry by pressing [▼] and proceed to the next line.
<Operation>
・
The character string which is set in the operand field is transmitted. Use this command to transmit a short
character string.
・
Each protocol has different way of transmission. Refer to following table.
MODBUS: Add BCC code automatically for RTU mode and transmit.
Operand Field: Specify the table group in the 1st digit, and the table No. in the 2nd digit with 00~9F.
Protocol
Contents of Data Transmission
ASYNC
If the character string for transmission includes BCC calculation start and stop charac-
ters, the BCC code is inserted and transmitted automatically.
SYNC
・
BSC
The SYNC character and the RST character are automatically inserted to data and
transmitted. In addition, if the character string for transmission includes BCC calcula-
tion start and stop characters, the BCC code is added automatically.
HDLC
・
SDLC
The flag and the FCS code are automatically inserted to data, and are transmitted.
ASYNC-PPP
If transmission data forms a frame, the FCS code is automatically inserted and transmitted.
MODBUS
Add BCC code automatically for RTU mode and transmit.
2 ) SEND TBL□□ (Data Table Transmission Command)
<Entering>
Cursor Position
Enter & Operation
Command Field 1
Sub-Command Field 1
Operand Field
Specify the table group in the 1st digit, and the table No. in the 2nd digit with 00~9F.
<Operation>
・
Data, which is in the transmission data table on the number being set in the operand field, is transmitted.
Use this command to send multi character strings.
4.1 Register Transmission Data
3 ) SEND REG□ GRP□ (Register-Specified Data Table Transmission Command)
<Entering>
Cursor Position
Enter & Operation
Command Field 1
Sub-Command Field 2
Operand Field
Enter a register number with [0] to [F] keys and a table group number with [0] to [9] keys.
By [END/X]:* (Don't care), all the groups will be the target.
NOP Command (Invalid Command)
The NOP command, which is displayed as “,” is the command that has no impact on the program execution.
<Entering>
Cursor Position
Enter & Operation
Command Field
0
Sub-Command Field -
Operand Field
-
<Operation>
・
When the program is running, the NOP command is ignored and the instruction of the next line number is
executed.