-50-
ڦ
Copy table
Touch “ ” -> “Copy table” and select the Group No. and Table No.
◆
HEX value of pre-set characters ([SHIFT] + [0] to [8]) are changed according to the selected data code in
"
Configuration
" setting. Refer to following table.
◆
Characters, which are not defined in the code table, are ignored.
*1 : THE QUICK BROWN FOX JUMPS OVER A LAZY DOG 0123456789.
*2 : S
X
0123456789ABCDEFGHIJKLMNOPQRSTUVWXYZE
X
BCC
*3 : 0123456789ABCDEFGHIJKLMNOPQRSTUVWXYZ C
R
L
F
[SHIFT]+[0]
ENQ
[SHIFT]+[7]
RVI
[SHIFT]+[1]
ACK
[SHIFT]+[8]
TTD
[SHIFT]+[2]
NAK
[SHIFT]+[9]
‘ FOX ’ Message
(*1)
[SHIFT]+[3]
WACK
[SHIFT]+[A]
‘ MSG1 ’ Message
(*2)
[SHIFT]+[4]
EOT
[SHIFT]+[B]
‘ MSG2 ’ Message
(*3)
[SHIFT]+[5]
ACK0
[SHIFT]+[C]
DC1 (11h)
[SHIFT]+[6]
ACK1
[SHIFT]+[D]
DC3 (13h)
ASCII/JIS/HEX
EBCDIC/EBCDIK
Transcode
Others
ENQ
05h
2Dh
2Dh
-
ACK
06h
2Eh
3Ch
-
NAK
15h
3Dh
3Dh
-
WACK
10h
・
3Bh
10h
・
6Bh
1Fh
・
26h
-
EOT
04h
37h
1Eh
-
ACK0
10h
・
30h
10h
・
70h
1Fh
・
20h
-
ACK1
10h
・
31h
10h
・
61h
1Fh
・
23h
-
RVI
10h
・
3Ch
10h
・
7Ch
1Fh
・
32h
-
TTD
02h
・
05h
02h
・
2Dh
0Ah
・
2Dh
-
ڦ
Copy buffer
It is able to copy monitored data into the table. At first, dis
-
play monitored data on the screen and adjust the head of data
to be copied on the upper left of screen. Touch “
” -> “Copy
buffer” and select “TXD data” or “RXD data” and copy size.
Touch “Execute” or press [ENTER].
Idle time and time stamp are not copied.
Fixed Transmission Data (Pre-set data)
Special characters like ENQ, ACK, etc. can be inputted. Touch “ ” -> “Copy table” -> “Fixed data”.
Also, they can be inputted with following shift keys.