LMAIM1501
LY Installation and Maintenance for LY 1001, LY 2001 and LY 3001
7-5
Install Input Worm Motor Pinion Assembly
18. Install Input Worm Motor Pinion Assembly (pieces #52, 156, 53, 124, and 31) into the Housing.
19. Install Housing Seal (O-Ring) (pieces #131).
Grease Unit
20. Grease unit with the properly recommended grease. (See Section 7.1, Lubrication.)
Install Top Plate
21. Install Top Plate (piece #2) and Hardware (pieces #65 and 66).
NOTE: If Top Plate will not fit properly, check Ball Bearing (piece #33) and Declutch Shaft (piece #44) for
proper alignment into Top Plate molding.
Install Torque Switch Assembly, Motor Assembly, and Limit Assembly
22. Install Torque Switch Assembly (piece #8) with Gasket and Hardware (piece #98 and 97).
23. Install Limit Switch Assembly (piece #7) and Heater Assembly (piece #120) with Hardware (piece #77, 78, 79,
and 80).
24. Reconnect Limit Switch, Torque Switch, and Terminal Strip. (See the wiring diagram included with the actuator
for proper wiring configuration.)
Install Control Cover
NOTE: Before installing the Control Cover, reset the Limit Switches and Mechanical Stops. Recheck motor for
proper rotation.
25. Install Cover Seal O-Ring (piece #130).
26. Install Control Cover (piece #3) with Hardware (piece #67 and 68).
7.3.3
LY 2001/3001 Disassembly
a
DANGER: HAZARDOUS VOLTAGE. Turn off all power before disassembling your LY actuator.
a
DANGER: POTENTIAL HIGH-PRESSURE VESSEL. Before disassembling your actuator, ensure that the valve or
other actuated device is isolated and is not under pressure.
Piece numbers refer to Figures 6.8, 6.9, 6.10, and 6.11.
Remove Cover and Top Plate
1.
Shut off all power to the actuator.
2.
Remove the Control Cover (piece #3).
3.
Disconnect all electrical leads from the Torque Switch (piece #8) and Limit Switch (piece #7). Make sure all
wire leads are properly marked for reassembly.
4.
Remove all external wires to the Terminal Strips (piece #9, 110, and 111).
5.
If unit has an Integral Assembly, remove all wires from the Integral Assembly to the Terminal Strip (piece #9,
110, and 111).
6.
Remove Screws/Lockwashers (piece #79 and 80) that are holding the Limit Switch (piece #7). Remove the
Limit Switch.
7.
Remove two Screws (piece #97) and two Lockwashers (piece #98) that are holding the Torque Switch (piece
#8). Remove the Torque Switch.
8.
Remove two Screws (piece #88) and two Lockwashers (piece #89) to remove the Top Plate (piece #2).
9.
Lift Top Plate (piece #2) off the LY Housing (piece #1). The Motor (piece #6) can be left attached to the Top
Plate when the Top Plate is removed.
Flow Control Division
Limitorque Actuation Systems